BS 648:1964
Withdrawn
Withdrawn
Schedule of weights of building materials
Available format(s)
Hardcopy , PDF
Language(s)
English
Published date
12-31-1964
Publisher
Withdrawn date
12-13-2011
US$450.07
Excluding Tax where applicable
NO CONTENTS SECTION
Data for structural calculations (weights given as approximate average with tolerances, or quoted as ranges); materials; measurements (in feet) and sizes (in inches) with metric equivalents; wire and sheet gauges (tabulated); index.
| Committee |
B/525/1
|
| DevelopmentNote |
Reviewed and Confirmed by BSI, April 2006. (04/2006)
|
| DocumentType |
Standard
|
| Pages |
50
|
| PublisherName |
British Standards Institution
|
| Status |
Withdrawn
|
| Standards | Relationship |
| UNE-EN 61746:2003 | Identical |
| ISO 9194:1987 | Similar to |
| DD ENV 1993-1.3 : 2001 AMD 13403 | EUROCODE 3: DESIGN OF STEEL STRUCTURES - PART 1.3: GENERAL RULES - SUPPLEMENTARY RULES FOR COLD FORMED THIN GAUGE MEMBERS AND SHEETING |
| BS 5061:1974 | Specification for cylindrical forage tower silos and recommendations for their use |
| 17/30349707 DC : DRAFT AUG 2017 | BS 5975:2018 - CODE OF PRACTICE FOR TEMPORARY WORKS PROCEDURES AND THE PERMISSIBLE STRESS DESIGN OF FALSEWORK |
| DD ENV 1992-1.1 : DRAFT MAY 1992 | EUROCODE 2: DESIGN OF CONCRETE STRUCTURES - GENERAL RULES FOR BUILDINGS (TOGETHER WITH UNITED KINGDOM NATIONAL APPLICATION DOCUMENT) |
| BS 5395-1:1977 | Stairs, ladders and walkways Code of practice for the design of straight stairs |
| BS 5502-22:1993 | Buildings and structures for agriculture Code of practice for design, construction and loading |
| BS 5975(2008) : 2008 | CODE OF PRACTICE FOR TEMPORARY WORKS PROCEDURES AND THE PERMISSIBLE STRESS DESIGN OF FALSEWORK |
| BS 8297:2000 | Code of practice for Design and installation of non-loadbearing precast concrete cladding |
| BS 5974:1990 | Code of practice for temporarily installed suspended scaffolds and access equipment |
| BS 8298-4:2010 | Code of practice for the design and installation of natural stone cladding and lining Rainscreen and stone on metal frame cladding systems |
| BS 5268-7.6:1990 | Structural use of timber. Recommendations for the calculation basis for span tables Purlins supporting rafters |
| BS 5268-7.2:1989 | Structural use of timber. Recommendations for the calculation basis for span tables Joists for flat roofs |
| I.S. 193:2006 | TIMBER TRUSSES FOR ROOFS |
| BS 5400-2:2006 | Steel, concrete and composite bridges Specification for loads |
| BS 6399-1:1996 | Loading for buildings Code of practice for dead and imposed loads |
| BS 5395-1:2000 | Stairs, ladders and walkways Code of practice for the design, construction and maintenance of straight stairs and winders |
| BS 5977-1:1981 | Lintels Method for assessment of load |
| BS 5268-7.1:1989 | Structural use of timber. Recommendations for the calculation basis for span tables Domestic floor joists |
| 07/30140559 DC : 0 | BS 8298-4 - CODE OF PRACTICE FOR THE DESIGN AND INSTALLATION OF NATURAL STONE CLADDING AND LINING - PART 4: RAINSCREEN AND STONE ON METAL FRAME CLADDING SYSTEMS |
| DD ENV 1996-1.1 : DRAFT DEC 1996 | EUROCODE 6: DESIGN OF MASONRY STRUCTURES - GENERAL RULES FOR BUILDINGS - GENERAL RULES FOR BUILDINGS - RULES FOR REINFORCED AND UNREINFORCED MASONRY (TOGETHER WITH UNITED KINGDOM NATIONAL APPLICATION DOCUMENT) |
| BS 5268-7.4:1989 | Structural use of timber Ceiling binders |
| 07/30016130 DC : 0 | BS 5974 - CODE OF PRACTICE FOR THE PLANNING, DESIGN, SETTING UP AND USE OF TEMPORARILY INSTALLED SUSPENDED ACCESS EQUIPMENT |
| BS CP118(1969) : 1969 AMD 1129 | THE STRUCTURAL USE OF ALUMINIUM |
| ENV 1993-1-3:1996/AC:1997 | EUROCODE 3: DESIGN OF STEEL STRUCTURES - GENERAL RULES - SUPPLEMENTARY RULES FOR COLD FORMED THIN GAUGE MEMBERS AND SHEETING |
| BS 5268-7.3:1989 | Structural use of timber. Recommendations for the calculation basis for span tables Ceiling joists |
| 04/30071550 DC : DRAFT JUNE 2004 | BS 5400-2 - STEEL, CONCRETE AND COMPOSITE BRIDGES - PART 2: SPECIFICATION FOR LOADS |
| 07/30150912 DC : 0 | BS 5975 - CODE OF PRACTICE FOR THE PROCEDURAL CONTROL OF TEMPORARY WORKS AND THE PERMISSIBLE STRESS DESIGN OF FALSEWORK |
| BS 5268-7.5:1990 | Structural use of timber. Recommendations for the calculation basis for span tables Domestic rafters |
| BS 5268-7.7:1990 | Structural use of timber. Recommendations for the calculation basis for span tables Purlins supporting sheeting or decking |
| BS 8297:1995 | Code of practice for design and installation of non-loadbearing precast concrete cladding |
| BS 5975:1996 | Code of practice for falsework |
Summarise