BS 7526(1991) : 1991 AMD 7980
Superseded
Superseded
View Superseded by
METHODS OF EVALUATING THE PERFORMANCE OF ELECTROMAGNETIC FLOWMETERS
Published date
11-23-2012
Publisher
Superseded date
10-15-1993
Superseded by
Sorry this product is not available in your region.
Recommends test methods for the evaluation of electromagnetic flowmeters for liquids flowing in closed conduits. Applies only to industrialized pipe-mounted electromagnetic flow-meters. Not applicable to insertion-type flow-meters, liquid-metal flow-meters and medical flow-meters, although some of the tests described may be applied. Covers normative references, definitions, general testing procedure, evaluation of the effect of an influence quality and tests for the evaluation of the effects of other influence quantities. BS AMD 7980 RENUMBERS THIS STANDARD TO BS EN 29104
| Committee |
PCL/2
|
| DevelopmentNote |
Renumbered and superseded by BS EN 29104. (03/2008)
|
| DocumentType |
Standard
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| ISO 9104:1991 | Identical |
| BS EN ISO 6817:1997 | Measurement of conductive liquid flow in closed conduits. Method using electromagnetic flowmeters |
| ISO 7066-2:1988 | Assessment of uncertainty in the calibration and use of flow measurement devices — Part 2: Non-linear calibration relationships |
| IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
| ISO 5168:2005 | Measurement of fluid flow — Procedures for the evaluation of uncertainties |
| IEC 60068-2-3:1969 | Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state |
| ISO 8316:1987 | Measurement of liquid flow in closed conduits — Method by collection of the liquid in a volumetric tank |
| ISO 6817:1992 | Measurement of conductive liquid flow in closed conduits — Method using electromagnetic flowmeters |
| ISO/TR 7066-1:1997 | Assessment of uncertainty in calibration and use of flow measurement devices — Part 1: Linear calibration relationships |
| ISO 3966:2008 | Measurement of fluid flow in closed conduits — Velocity area method using Pitot static tubes |
| ISO 4006:1991 | Measurement of fluid flow in closed conduits — Vocabulary and symbols |
Summarise