BS EN 16758:2016
Superseded
View Superseded by
Curtain walling. Determination of the strength of sheared connections. Test method and requirements
Hardcopy , PDF
English
06-30-2016
05-28-2021
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols
5 Method of evaluation
7 Test report
Annex A (informative) - Determination of the design loading
of a connection Serviceability limit state
Annex B (normative) - Determination of the design loading
of a connection - Ultimate limit state
Annex C (normative) - Field of direct application
Bibliography
Gives test methods for the determination of bearing capacity (ultimate limit state and serviceability limit state), of connections between curtain walling framing members for which it cannot be calculated in accordance with current codes or conventional calculations based upon the strength of the materials.
| Committee |
B/538/6
|
| DocumentType |
Standard
|
| Pages |
24
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy |
This European Standard specifies test methods for the determination of bearing capacity (ultimate limit state and serviceability limit state), of connections between curtain walling framing members for which it cannot be calculated in accordance with current codes or conventional calculations based upon the strength of the materials. Mechanical performances of the curtain walling connections are already assessed in accordance with the provisions described in EN 13830 . Additional information with respect to mechanical performance of the connections and direct applications can be determined with this standard.
| Standards | Relationship |
| EN 16758:2016 | Identical |
| DIN EN 16758:2016-12 | Equivalent |
| I.S. EN 16758:2016 | Equivalent |
| ISO 16269-6:2014 | Statistical interpretation of data — Part 6: Determination of statistical tolerance intervals |
| EN 13830:2015 | Curtain walling - Product standard |
| EN 13119:2016 | Curtain walling - Terminology |