• There are no items in your cart

BS EN 17175:2019

Current

Current

The latest, up-to-date edition.

Gas-fired overhead radiant strip heaters and multi-burner continuous radiant tube heater systems for non-domestic use. Safety and energy efficiency

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

02-05-2020

This document specifies the requirements and test methods for the construction, safety, classification, marking and efficiency of non-domestic gas-fired overhead radiant strips heaters and multi-burner continuous radiant tube heater systems (referred to in the body of the text as the “system”) with each burner unit under the control of an automatic burner control system. For radiant strip heaters incorporating a single burner, this standard is applicable to Type B22, B23, B52, B53, C12, C13, C32, C33 C52 and C53 appliances intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means. For multi-burner continuous radiant tube heater systems this standard is applicable to type B22, B52, and C52 appliances intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means. This document also includes appliances incorporating a secondary heat exchanger in the flue system. This document is not applicable to: appliances designed for use in domestic dwelling; outdoor appliances; radiant strip heaters where the heat input is in excess of 300 KW (based on the net calorific value of the appropriate reference test gas); continuous radiant tube heater systems where the heat input of any individual burner unit is in excess of 70 kW (based on the net calorific value of the appropriate reference test gas); appliances having combustion products evacuation ducts that are non-metallic in the flue system – except ducts downstream of a possible additional condensing exhaust gas heat exchanger. In addition, for heater systems incorporating multiple tube heaters this standard is not applicable to: appliances that are designed for continuous condensation within the flue system under normal operating conditions – except downstream a possible additional exhaust gas heat exchanger. This document is applicable to appliances which are intended to be type tested.

Committee
GSE/20
DocumentType
Standard
Pages
166
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
EN 17175:2019 Identical

View more information
US$367.73
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.