BS EN 50290-2-25:2013
Current
Communication cables Common design rules and construction. Polypropylene insulation compounds
Hardcopy , PDF
English
11-30-2013
Foreword
1 Scope
2 Normative references
3 Compound test requirements
4 Cable test requirements
5 Health, Safety and Environmental Regulations
Bibliography
Provides specific requirements for PP compounds to be used for multi-element metallic data cables for indoor application.
| Committee |
EPL/46
|
| DevelopmentNote |
To be read in conjunction with BS EN 50290-2-20 Supersedes BS 7878-5(1997) and 00/245016 DC (04/2002) Supersedes 13/30281390 DC. (11/2013)
|
| DocumentType |
Standard
|
| Pages |
14
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
This European Standard gives specific requirements for PP compounds to be used for multi-element metallic data cables for indoor application. Type 1 is typically a copolymer with better low temperature properties. Type 2 is typically a homopolymer with superior hardness giving better crush resistance.
Using compound and type test data as outlined in this standard, the compound supplier will have sufficient data to demonstrate compliance and warrant that the material is suitable for the specified application.
| Standards | Relationship |
| DIN EN 50290-2-25:2014-09 | Identical |
| I.S. EN 50290-2-25:2013 | Identical |
| NEN EN 50290-2-25 : 2013 | Identical |
| EN 50290-2-25:2013 | Identical |
| UNE-EN 50290-2-25:2014 | Identical |