BS EN 50363-1:2005
Current
Insulating, sheathing and covering materials for low voltage energy cables Cross-linked elastomeric insulating compounds
Hardcopy , PDF
English
02-03-2006
1 Scope
2 Normative references
3 Definitions
4 Properties
Tables
Defines the requirements for the cross-linked elastomeric insulating compounds.
| Committee |
GEL/20/17
|
| DevelopmentNote |
Supersedes BS 7655-1.1(2000) (02/2006) Supersedes 02/202787 DC. To be read in conjunction with BS EN 50363-0. (03/2006)
|
| DocumentType |
Standard
|
| Pages |
10
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
This part of EN 50363 specifies the requirements for the cross-linked elastomeric insulating compounds given in Table 1. The relevant test methods are given in EN 60811 series and EN 50396. NOTE This part of EN 50363 is to be read in conjunction with EN 50363-0. Table 1 – Types of cross-linked elastomeric insulating compound Type Maximum material operating temperature °C General application EI 2 180 Ordinary duty silicone rubber (SiR) EI 3 110 Ordinary duty EVA rubber or equivalent EI 4 60 Ordinary duty ethylene propylene rubber EI 6 90 Ordinary duty ethylene-propylene rubber or equivalent synthetic elastomer for cables requiring handling down to –40 °C EI 7 90 Ordinary duty ethylene propylene rubber or equivalent synthetic elastomer
| Standards | Relationship |
| IEC 60352-5:2008 | Identical |
| NEN EN 50363-1 : 2006 | Identical |
| I.S. EN 50363-1:2005 | Identical |
| NF EN 50363-1 : 2006 | Identical |
| EN 50363-1:2005 | Identical |
| NBN EN 50363-1 : 2006 | Identical |
| DIN EN 50363-1:2006-10 | Identical |
| UNE-EN 50363-1:2006 | Identical |