BS EN 54-22:2015
Superseded
View Superseded by
Fire detection and fire alarm systems Resettable line-type heat detectors
Hardcopy , PDF
English
05-31-2015
04-10-2020
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Product characteristics
5 Testing, assessments and sampling methods
6 Assessment and verification of constancy of
performance (AVCP)
7 Classification
8 Marking, labelling and packaging
Annex A (normative) - Arrangement of the sensing
element in the fire test room
Annex B (normative) - Flaming liquid test fires
(TF6F, TF6 and TF6S)
Annex C (normative) - Test arrangement for the
sensing element of linear heat detector in
the heat tunnel
Annex D (informative) - Apparatus for mounting of the
sensing element of linear heat detector in the
heat tunnel
Annex E (normative) - Mounting of the sensing element
of multipoint RLTHD in the heat tunnel
Annex F (normative) - Heat tunnel for response time and
of multipoint RLTHD in the heat tunnel
Annex F (normative) - Heat tunnel for response time and
response temperature measurements
Annex G (informative) - Construction of the heat
tunnel
Annex H (normative) - Test arrangement for vibration tests
for sensing element
Annex I (normative) - Test apparatus for impact test on the
sensing element
Annex J (informative) - Data supplied with resettable
line-type heat detectors
Annex ZA (informative) - Clauses of this European Standard
addressing the provisions of the EU Construction
Products Regulation
Bibliography
Pertains to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works.
| Committee |
FSH/12/2
|
| DevelopmentNote |
Supersedes 11/30240275 DC. (05/2015)
|
| DocumentType |
Standard
|
| Pages |
88
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
This European Standard applies to resettable line-type heat detectors consisting of a sensing element using an optical fibre, a pneumatic tube or an electrical sensor cable connected to a sensor control unit, either directly or through an interface module, intended for use in fire detection and fire alarm systems installed in and around buildings and other civil engineering works (see EN54‑1:2011 ). This European Standard specifies the requirements and performance criteria, the corresponding test methods and provides for the Assessment and Verification of Constancy of Performance (AVCP) of resettable line-type heat detectors to this EN. This European Standard also covers resettable line-type heat detectors intended for use in the local protection of plant and equipment. Resettable line-type heat detectors with special characteristics and developed for specific risks are not covered by this EN. This European Standard does not cover line-type heat detectors that are based on non-resettable, fixed temperature electrical cables (so called “digital?? systems).
| Standards | Relationship |
| EN 54-22:2015 | Identical |
| DIN EN 54-22:2015-07 | Equivalent |
| I.S. EN 54-22:2015 | Equivalent |
A newer version of this standard is available.
View Current Edition