BS EN 60076-1:2011
Current
Power transformers General
Hardcopy , PDF
English
07-31-2012
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions
5 Rating and general requirements
6 Requirements for transformers having a tapped winding
7 Connection phase displacement symbols
8 Rating plates
9 Safety, environmental and other requirements
10 Tolerances
11 Tests
12 Electromagnetic compatibility (EMC)
13 High frequency switching transients
Annex A (informative) - Check list of information to be
provided with enquiry and order
Annex B (informative) - Examples of specifications for
transformers with tappings
Annex C (informative) - Specification of short-circuit
impedance by boundaries
Annex D (informative) - Examples of three-phase transformer
connections
Annex E (normative) - Temperature correction of load loss
Annex F (informative) - Facilities for future fitting of
condition monitoring systems to transformers
Annex G (informative) - Environmental and safety considerations
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Bibliography
Pertains to three-phase and single-phase power transformers (including auto-transformers) with the exception of certain categories of small and special transformers.
| Committee |
PEL/14
|
| DevelopmentNote |
Supersedes BS 171-1(1978) and BS 171-4(1978) (07/2001) Supersedes 01/206406 DC, 90/23125 and 97/204142 DC (07/2002) Supersedes 07/30167951 DC. (11/2011)
|
| DocumentType |
Standard
|
| Pages |
78
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
This part of IEC 60076 applies to three-phase and single-phase power transformers (including auto-transformers) with the exception of certain categories of small and special transformers such as:
single-phase transformers with rated power less than 1 kVA and three-phase transformers less than 5 kVA;
transformers, which have no windings with rated voltage higher than 1 000 V;
instrument transformers;
traction transformers mounted on rolling stock;
starting transformers;
testing transformers;
welding transformers;
explosion-proof and mining transformers;
transformers for deep water (submerged) applications.
When IEC standards do not exist for such categories of transformers (in particular transformer having no winding exceeding 1000 V for industrial applications), this part of IEC 60076 may still be applicable either as a whole or in part.
This standard does not address the requirements that would make a transformer suitable for mounting in a position accessible to the general public.
For those categories of power transformers and reactors which have their own IEC standards, this part is applicable only to the extent in which it is specifically called up by cross-reference in the other standard. Such standards exist for:
reactors in general (IEC 60076-6);
dry-type transformers (IEC 60076-11);
self-protected transformers (IEC 60076-13);
gas-filled power transformers (IEC 60076-15);
transformers for wind turbine applications (IEC 60076-16);
traction transformers and traction reactors (IEC 60310);
converter transformers for industrial applications (IEC 61378-1);
converter transformers for HVDC applications (IEC 61378-2).
At several places in this part it is specified or recommended that an \'agreement\' should be reached concerning alternative or additional technical solutions or procedures. Such agreement is made between the manufacturer and the purchaser. The matters should preferably be raised at an early stage and the agreements included in the contract specification.
| Standards | Relationship |
| DIN EN 60076-1:2012-03 | Identical |
| NF EN 60076-1 : 2012 | Identical |
| I.S. EN 60076-1:2011 | Identical |
| IEC 60076-1:2011 | Identical |
| NBN EN 60076-1 : 2011 | Identical |
| EN 60076-1:2011 | Identical |
| UNE-EN 60076-1:2013 | Identical |