• Shopping Cart
    There are no items in your cart
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

BS EN 60079-10-2:2015

Current

Current

Explosive atmospheres Classification of areas. Explosive dust atmospheres

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

03-31-2015

US$333.50
Excluding Tax where applicable
Summarise this standard

Committee
EXL/31
DevelopmentNote
Supersedes BS EN 61241-10 & 07/30162732 DC. (10/2009)
DocumentType
Standard
Pages
30
PublisherName
British Standards Institution
Status
Current
Supersedes

This part of IEC60079 is concerned with the identification and classification of areas where explosive dust atmospheres and combustible dust layers are present, in order to permit the proper assessment of ignition sources in such areas. In this standard, explosive dust atmospheres and combustible dust layers are treated separately. In Clause4, area classification for explosive dusts clouds is described, with dust layers acting as one of the possible sources of release. In Clause7 other general considerations for dust layers are described. The examples in this standard are based on a system of effective housekeeping being implemented in the plant to prevent dust layers from accumulating. Where effective housekeeping is not present, the area classification includes the possible formation of explosive dust clouds from dust layers. The principles of this standard can also be followed when combustible fibres or flyings might cause a hazard. This standard is intended to be applied where there can be a risk due to the presence of explosive dust atmospheres or combustible dust layers under normal atmospheric conditions (see Note1). NOTE1 Atmospheric conditions include variations in pressure and temperature above and below reference levels of 101,3kPa (1013mbar) and 20°C (293K), provided that the variations have a negligible effect on the explosive properties of the combustible materials. It does not apply to underground mining areas, dusts of explosives that do not require atmospheric oxygen for combustion such as pyrophoric substances, propellants, pyrotechnics, munitions, peroxides, oxidizers, water-reactive elements or compounds, or other similar materials. catastrophic failures which are beyond the concept of abnormality dealt with in this standard, any risk arising from an emission of toxic gas from the dust. This standard does not apply to where a hazard might arise due to the presence of flammable gas or vapour, but the principles may be used in the assessment of a hybrid mixture (see also IEC60079‑10‑1 ). NOTE2 Additional guidance on hybrid mixtures is provided in AnnexC. This standard does not take into account the effects of consequential damage following a fire or an explosion.

Standards Relationship
IEC 60079-10-2:2015 Identical
EN 60079-10-2:2015 Identical
I.S. EN 60079-10-2:2015 Equivalent
DIN EN 60079-10-2:2015-10 Equivalent

US$333.50
Excluding Tax where applicable