BS EN 61249-2-39:2013
Current
Materials for printed boards and other interconnecting structures Reinforced base materials clad and unclad. High performance epoxide and non-epoxide, woven E-glass laminate sheets of defined flammability (vertical burning test), copper-clad for lead-free assembly
Hardcopy , PDF
English
04-30-2013
1 Scope
2 Normative references
3 Materials and construction
4 Internal marking
5 Electrical properties
6 Non-electrical properties of the copper-clad laminate
7 Non-electrical properties of the base material after
complete removal of the copper foil
8 Quality assurance
9 Packaging and marking
10 Ordering information
Annex A (informative) - Engineering information
Annex B (informative) - Common laminate constructions
Annex C (informative) - Guideline for qualification
and conformance inspection
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Describes requirements for properties of modified brominated epoxide woven E-glass laminated sheet of a thickness 0,05 mm up to 3,2 mm, of defined flammability (vertical burning test), copper-clad.
| Committee |
EPL/501
|
| DevelopmentNote |
Supersedes 09/30211075 DC. (04/2013)
|
| DocumentType |
Standard
|
| Pages |
28
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
This part of IEC 61249 specifies requirements for properties of modified brominated epoxide woven E-glass laminated sheet of a thickness 0,05 mm up to 3,2 mm, of defined flammability (vertical burning test), copper-clad. The glass transition temperature is defined to be 170 °C minimum.
Its flame resistance is defined in terms of the flammability requirements of 7.3.
Some property requirements may have several classes of performance. The class desired should be specified on the purchase order, otherwise the default class of material will be supplied.
| Standards | Relationship |
| IEC 61249-2-39:2012 | Identical |
| EN 61249-2-39:2013 | Identical |
| EN 61000-4-12:2006 | Identical |
| I.S. EN 61249-2-39:2013 | Equivalent |
| DIN EN 61249-2-39:2013-09 | Equivalent |
| UNE-EN 61249-2-39:2013 | Equivalent |