BS EN 61439-4:2013
Current
Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies for construction sites (ACS)
Hardcopy , PDF
English
03-31-2013
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Interface characteristics
6 Information
7 Service conditions
8 Constructional requirements
9 Performance requirements
10 Design verification
11 Routine verification
101 Particular features of ACS
Annex C (informative) - User information template
Annex D (informative) - Design verification
Annex O (informative) - Guidance on temperature rise
verification
Annex P (normative) - Verification of the short-circuit
withstand strength of busba structures by
comparison with a tested reference design by
calculation
Annex AA (informative) - List of notes concerning
certain countries
Annex BB (Void)
Annex CC (informative) - Items subject to agreement
between the ASSEMBLY manufacturer and the user
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Annex ZB (normative) - Special national conditions
Annex ZZ (informative) - Coverage of Essential
Requirements of EU Directive 2004/108/EC
Describes the specific requirements of ACS as follows: - ASSEMBLIES for which the rated voltage does not exceed 1000 V in case of a.c. or 1500 V in case of d.c.; - ASSEMBLIES where the nominal primary voltage and the nominal secondary voltage of transformers incorporated in ACS are within the limits specified above; - ASSEMBLIES intended for use on construction sites, both indoors and outdoors, i.e. temporary places of work to which the public do not generally have access and where building construction, installation, repairs, alteration or demolition of property (buildings) or civil engineering (public works) or excavation or any other similar operations are carried out; - transportable (semi-fixed) or mobile ASSEMBLIES with enclosure.
| Committee |
PEL/121/2
|
| DevelopmentNote |
Supersedes BS EN 60439-4 & 10/30218813 DC. (04/2013)
|
| DocumentType |
Standard
|
| Pages |
36
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
IEC 61439-4:2012 defines the specific requirements of ACS as follows:
- ASSEMBLIES for which the rated voltage does not exceed 1 000 V in case of a.c. or 1 500 V in case of d.c.;
- ASSEMBLIES where the nominal primary voltage and the nominal secondary voltage of transformers incorporated in ACS are within the limits specified above;
- ASSEMBLIES intended for use on construction sites, both indoors and outdoors, i.e. temporary places of work to which the public do not generally have access and where building construction, installation, repairs, alteration or demolition of property (buildings) or civil engineering (public works) or excavation or any other similar operations are carried out;
- transportable (semi-fixed) or mobile ASSEMBLIES with enclosure. The manufacture and/or assembly may be carried out other than by the original manufacturer. This first edition of IEC 61439-4 cancels and replaces the second edition of IEC 60439-4 (2004), and constitutes a technical revision. This edition includes the following significant technical changes with respect to the last edition of IEC 60439-4:
- modification of the title as \'Part 4: Particular requirements for assemblies for construction sites (ACS)\';
- alignment on IEC 61439-1 regarding the structure and technical content, as applicable;
- to allow comparison with tested ACS.
This publication is to be read in conjunction with IEC 61439-1:2011.
| Standards | Relationship |
| EN 61439-4:2013 | Identical |
| IEC 61439-4:2012 | Identical |
| I.S. EN 61439-4:2013 | Equivalent |
| UNE-EN 61439-4:2013 | Equivalent |