IEC 60364-5-54:2011
|
Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors
|
IEC 60038:2009
|
IEC standard voltages
|
IEC 60068-2-5:2010
|
Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing
|
IEC 60364-4-43:2008
|
Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent
|
EN 60068-2-75:2014
|
Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
|
EN 61000-4-1:2007
|
Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
|
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION)
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
|
IEC 61000-4-1:2006
|
Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
|
IEC 60950:1999
|
Safety of information technology equipment
|
EN 61000-4-11:2004/A1:2017
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
|
EN 60068-2-1:2007
|
Environmental testing - Part 2-1: Tests - Test A: Cold
|
EN 60068-2-2:2007
|
Environmental testing - Part 2-2: Tests - Test B: Dry heat
|
IEC 61000-4-11:2004+AMD1:2017 CSV
|
Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
|
EN 60950:2000/corrigendum:2002
|
SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT
|
HD 625.1 : 200S1
|
INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PRINCIPLES, REQUIREMENTS AND TESTS
|
HD 384.4.443 S1:2000
|
ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 44: PROTECTION AGAINST OVERVOLTAGES - SECTION 443: PROTECTION AGAINST OVERVOLTAGES OF ATMOSPHERIC ORIGIN OR DUE TO SWITCHING
|
IEC 61000-4-4:2012 RLV
|
Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
|
EN 61000-4-2:2009
|
Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
|
HD 472 S1:1989/AC:2013
|
NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS
|
CISPR 22:2008
|
Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
|
EN 61000-4-3 : 2006 AMD 2 2010
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
|
HD 384.4.43 : 200S2
|
ELECTRICAL INSTALLATIONS OF BUILDINGS - PROTECTION FOR SAFETY - CHAPTER 43: PROTECTION AGAINST OVERCURRENT
|
HD 323.2.3 : 200S2
|
BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST CA - DAMP HEAT, STEADY STATE
|
IEC 60068-2-3:1969
|
Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state
|
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV
|
Degrees of protection provided by enclosures (IP Code)
|
IEC 60068-2-2:2007
|
Environmental testing - Part 2-2: Tests - Test B: Dry heat
|
IEC 61000-4-2:2008
|
Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
|
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV
|
Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
|
IEC 60439-1:1999+AMD1:2004 CSV
|
Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies
|
IEC 61000-2-2:2002+AMD1:2017 CSV
|
Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
|
EN 61000-3-2:2014
|
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
|
EN 60439-1:1999/A1:2004
|
LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1 - TYPE TESTED AND PARTIALLY TYPE TESTED ASSEMBLIES
|
IEC 60364-4-443:1995+AMD1:1998 CSV
|
Electrical installations of buildings - Part 4: Protection for safety - Chapter 44: Protection against overvoltages - Section 443: Protection against overvoltages of atmospheric origin or due to switching
|
IEC 60068-2-75:2014
|
Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
|
EN 61000-4-4:2012
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
|
EN 61036:1996/A1:2000
|
ALTERNATING CURRENT STATIC WATT-HOUR METERS FOR ACTIVE ENERGY (CLASSES 1 AND 2)
|
CISPR 11:2015 RLV
|
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
|
IEC 60068-2-1:2007
|
Environmental testing - Part 2-1: Tests - Test A: Cold
|
IEC 61180-1:1992
|
High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements
|
EN 60529:1991/AC:2016-12
|
DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
|
EN 60068-2-5:2011
|
Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing
|
EN 60068-2-30:2005
|
Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
|
IEC 60068-2-14:2009
|
Environmental testing - Part 2-14: Tests - Test N: Change of temperature
|
IEC 60309-1:1999+AMD1:2005+AMD2:2012 CSV
|
Plugs, socket-outlets and couplers for industrial purposes - Part 1: General requirements
|
IEC 60664-1:2007
|
Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
|
EN 60068-2-14:2009
|
Environmental testing - Part 2-14: Tests - Test N: Change of temperature
|
IEC 60068-2-52:2017
|
Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
|
EN 61180-1:1994
|
High-voltage test techniques for low-voltage equipment - Part 1: Definitions, test and procedure requirements
|
IEC 61036:1996+AMD1:2000 CSV
|
Alternating current static watt-hour meters for active energy (classes 1 and 2)
|
IEC 61000-3-2 : 4.0
|
ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
|
IEC 60068-2-30:2005
|
Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
|