• Shopping Cart
    There are no items in your cart
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

BS EN 62305-2:2012

Superseded

Superseded

View Superseded by

Protection against lightning Risk management

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

04-30-2013

Superseded date

02-18-2025

Superseded by

BS EN IEC 62305-2:2024

US$500.25
Excluding Tax where applicable
Summarise this standard

Committee
GEL/81
DevelopmentNote
Together with BS EN 62305-1, BS EN 62305-3 and BS EN 62305-4, supersedes BS 6651(1999). Supersedes 03/305096 DC. (10/2006) Supersedes 07/30174633 DC. (05/2013) For revised maps, please see supplement BS PD62305-2(2014). (09/2014)
DocumentType
Standard
Pages
146
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

IEC 62305-2:2010 is applicable to risk assessment for a structure due to lightning flashes to earth. Its purpose is to provide a procedure for the evaluation of such a risk. Once an upper tolerable limit for the risk has been selected, this procedure allows the selection of appropriate protection measures to be adopted to reduce the risk to or below the tolerable limit. This second edition cancels and replaces the first edition, published in 2006, and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
1) Risk assessment for services connected to structures is excluded from the scope.
2) Injuries of living beings caused by electric shock inside the structure are considered.
3) Tolerable risk of loss of cultural heritage is lowered from 10 -3 to 10 -4. The value of tolerable risk of loss of economic value ( R T = 10 -3) is introduced, to be used when data for cost/benefit analysis are not available.
4) Extended damage to surroundings structures or to the environment is considered.
5) Improved equations are provided for evaluation of
- collection areas relevant to flashes nearby a structure,
- collection areas relevant to flashes to and nearby a line,
- probabilities that a flash can cause damage,
- loss factors even in structures with risk of explosion,
- risk relevant to a zone of a structure,
- cost of loss.
6) Tables are provided to select the relative amount of loss in all cases.
7) Impulse withstand voltage level of equipments was extended down to 1 kV.
This bilingual version corresponds to the monolingual English version, published in 2010-12.

Standards Relationship
DIN EN 62305-2 : 2013-02 Identical
EN 62305-2:2012 Identical
NF EN 62305-2 : 2012 Identical
I.S. EN 62305-2:2012 Identical
NBN EN 62305-2 : 2012 Identical
EN 60947-5-4:2003 Identical
UNE-EN 62305-2:2012 Equivalent
UNE-EN 62305-2:2007 Identical

⚠

A newer version of this standard is available.

View Current Edition
US$500.25
Excluding Tax where applicable