BS EN 62808:2016
Withdrawn
View Superseded by
Nuclear power plants. Instrumentation and control systems important to safety. Design and qualification of isolation devices
Hardcopy , PDF
English
10-31-2016
08-02-2019
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 General principles for isolation devices
6 Isolation device design requirements
7 Qualification test requirements
Bibliography
Annex ZA (normative) - Normative references
to international publications with their
corresponding European publications
Specifies requirements for the design, analysis and qualification of isolation devices used to ensure electrical independence of redundant safety system circuits, or between safety and lower class circuits, as specified in IEC 60709.
| Committee |
NCE/8
|
| DevelopmentNote |
Supersedes 14/30280764 DC. Renumbers and supersedes BS IEC 62808. 2016 version incorporates corrigendum to BS IEC 62808. (10/2016)
|
| DocumentType |
Standard
|
| Pages |
22
|
| PublisherName |
British Standards Institution
|
| Status |
Withdrawn
|
| SupersededBy | |
| Supersedes |
IEC 62808:2015 establishes requirements for the design, analysis and qualification of isolation devices used to ensure electrical independence of redundant safety system circuits, or between safety and lower class circuits, as specified in IEC 60709. This standard includes guidance on the determination of the maximum credible fault that is applied to the isolation devices. The maximum credible fault can be used as a basis for the test levels used in testing based on other standards (e.g. IEC TS 61000-6-5 or IEC 62003).
| Standards | Relationship |
| EN 62808:2016 | Identical |
| I.S. EN 62808:2016 | Equivalent |
| IEC 62808:2015+AMD1:2018 CSV | Identical |
| UNE-EN 62808:2016 | Equivalent |
A newer version of this standard is available.