• Shopping Cart
    There are no items in your cart
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

BS EN 88:1991

Superseded

Superseded

View Superseded by

Pressure governors for gas appliances for inlet pressures up to 200 mbar

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

11-29-1991

Superseded date

12-31-2007

US$391.00
Excluding Tax where applicable
Summarise this standard

Cooperating organizations
National foreword
Foreword
1. General
1.1 Object and field of application
1.2 References
1.3 Definitions
1.4 Classification
1.5 Measuring ratio
2. Construction requirements
2.1 General
2.2 Materials
2.3 Connections
2.4 Seals for glands for moving parts
2.5 Pressure test nipples
3. Performance requirements
3.1 General
3.2 Putting the governor out of action
3.3 External leak-tightness
3.4 Torsion and bending
3.5 Durability
3.6 Governor performance
3.7 text deleted
3.8 Durability of performance
3.9 Lock-up pressure
4. Test methods
4.1 General
4.2 Putting the governor out of action
4.3 External leak-tightness
4.4 Torsion and bending
4.5 Durability
4.6 Governor performance
4.7 text deleted
4.8 Durability of performance
4.9 Lock-up pressure
5. Marking, installation and operating instructions
5.1 Marking
5.2 Installation, operating and servicing instructions
5.3 Warning notice
Annexes
A. Characteristics of combustible gases
B. Typical governors and governor parts
C. Use of ISO 7-1: 1982 and ISO 228-1: 1982 threads
      for gas connections
D. Leak-tightness test - volumetric method
E. Leak-tightness test - pressure loss method
F. Conversion of pressure loss into leakage rate
G. Summary of requirements and test conditions
Tables
1. Connection sizes
2. Maximum external leakage rates
3. Torque and bending moment
4. Gas pressure at inlet to the governor
5. Outlet pressure variation from the outlet setting
      pressure
6. Sequence of testing
7. Tightening torque for flange bolts to ISO 7005-2:
      1988
Figures
1. Arrangement for torsion test
2. Arrangement for bending test
3. Paint scratch test apparatus
4. Governor performance test rig
5. Graph of performance using inlet pressure variation
6. Graph of performance using flow rate variation
7. Types of constant pressure governor (diagrammatic)
8. Apparatus for testing leak-tightness (volumetric
      method)
9. Apparatus for testing leak-tightness (pressure loss
      method)

Requirements and methods of test for pressure governors for use with gas appliances for nominal size up to and including DN 50. Does not cover governors connected directly to mains pipework or for installation out of doors and exposed to the environment.

Committee
GSE/22
DevelopmentNote
Supersedes 77/73411 DC and BS 6448-1(1987) (09/2005)
DocumentType
Standard
Pages
34
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
NS EN 88 : 1991 AMD 1 1996 Identical
I.S. EN 88:1992 Identical
NEN EN 88 : 1992 AMD 1 1996 Identical
EN 88:1991/A1:1996 Identical
NF EN 88 : 91 AMD 1 96 Identical
DIN EN 88:1996-08 Identical

⚠

A newer version of this standard is available.

View Current Edition View Current Edition
US$391.00