• Shopping Cart
    There are no items in your cart

BS EN ISO 12417-1:2015

Superseded

Superseded

View Superseded by

Cardiovascular implants and extracorporeal systems. Vascular device-drug combination products General requirements

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

10-31-2015

Superseded date

02-28-2024

Superseded by

BS EN ISO 12417-1:2024

US$462.87
Excluding Tax where applicable
Summarise this standard

Committee
CH/150/2
DevelopmentNote
Supersedes DD ISO/TS 12417 & 14/30251609 DC. (10/2015)
DocumentType
Standard
Pages
64
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This part of ISO12417 specifies requirements for vascular device-drug combination products (VDDCPs) based upon current technical and medical knowledge. VDDCPs are medical devices with various clinical indications for use in the human vascular blood system. A VDDCP incorporates, as an integral part, substance(s) which, if used separately, can be considered to be a medicinal substance or product (drug substance, drug product) but the action of the medicinal substance is ancillary to that of the device and supports the primary mode of action (PMOA) of the device. With regard to safety, this part of ISO12417 outlines requirements for intended performance, design attributes, materials, design evaluation, manufacturing, sterilization, packaging, and information supplied by the manufacturer. For implanted products, this International Standard should be considered as a supplement to ISO14630, which specifies general requirements for the performance of non-active surgical implants. This International Standard should also be considered as a supplement to relevant device-specific standards, such as the ISO25539‑series specifying requirements for endovascular devices. Requirements listed in this part of ISO12417 also address VDDCPs that are not permanent implants.

NOTE Due to variations in the design of combination products covered by this part of ISO12417 and due to the relatively recent development of some of these combination products, acceptable standardized in vitro test results and clinical study results are not always available. As further scientific and clinical data become available, appropriate revision of this part of ISO12417 might be necessary.

Delivery systems or parts of the delivery system are included in the scope of this part of ISO12417, if they comprise an integral component of the vascular device and if they are drug-covered (e.g. drug-covered balloon catheters and drug-covered guidewires).

Devices whose PMOA is to provide a conduit for delivery of a drug, are excluded from the scope of this part of ISO12417 (e.g. infusion catheters), unless they contain a drug component that is intended to have an ancillary action to the device part (e.g. antimicrobial coated infusion catheter).

Procedures and devices used prior to and following the introduction of the VDDCP (e.g. balloon angioplasty devices) are excluded from the scope of this part of ISO12417 if they do not affect the drug-related aspects of the device.

This part of ISO12417 is not comprehensive with respect to the pharmacological evaluation of VDDCPs. Some information on the requirements of different national and regional authorities is given in AnnexB.

Absorbable components of VDDCPs (e.g. coatings) are addressed by this part of ISO12417 in their connection with drug-related aspects of the device. Degradation and other time-dependent aspects of absorbable implants and coatings are not completely addressed by this part of ISO12417.

NOTE See also ISO/TS17137 and ASTMF3036-13.

This part of ISO12417 does not address issues associated with viable or non-viable biological materials such as tissues, cells, or proteins.

This part of ISO12417 does not address issues associated with active surgical implants (i.e. implants that require power not generated by the human body or gravity).

Standards Relationship
EN ISO 12417-1:2015 Identical
ISO 12417-1:2015 Identical
I.S. EN ISO 12417-1:2015 Equivalent

⚠

A newer version of this standard is available.

View Current Edition
US$462.87
Excluding Tax where applicable