BS EN ISO 2719:2002
Current
Determination of flash point. Pensky-Martens closed cup method
Hardcopy , PDF
English
07-21-2004
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Chemicals and materials
6 Apparatus
7 Apparatus preparation
8 Sampling
9 Sample handling
10 Procedure
11 Calculation
12 Expression of results
13 Precision
14 Test report
Annex A (informative) - Apparatus verification
Annex B (normative) - Pensky-Martens closed cup test
apparatus
Annex C (normative) - Temperature measuring device
specification
Bibliography
Defines three procedures, A, B and C, using the Pensky-Martens closed cup tester, for determining the flash point of combustible liquids, liquids with suspended solids, liquids that tend to form a surface film under the test conditions, biodiesel and other liquids in the temperature range of 40 degrees C to 370 degrees C.
| Committee |
PTI/13
|
| DevelopmentNote |
Supersedes 98/125094 DC and BS EN 22719 Renumbers and supersedes BS 2000-34(2002) (08/2004) Also numbered as BS 2000-34(2016). Supersedes 15/30301302 DC. (08/2016)
|
| DocumentType |
Standard
|
| Pages |
34
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| DIN EN ISO 2719:2003-09 | Identical |
| NEN EN ISO 2719 : 2016 | Identical |
| DIN EN ISO 2719:2015-07 (Draft) | Identical |
| I.S. EN ISO 2719:2016 | Identical |
| EN ISO 2719:2016 | Identical |
| NF EN ISO 2719 : 2003 | Identical |
| NS EN ISO 2719 : 2002 | Identical |
| ISO 2719:2016 | Identical |
| NBN EN ISO 2719 : 2003 | Identical |
| I.S. EN ISO 2719:2002 | Equivalent |
| ISO 2719:2002 | Identical |
| EN ISO 2719:2002 | Identical |
| EN ISO 2719:2002 | Equivalent |
| ISO 2719:2002 | Equivalent |
| UNE-EN ISO 2719:2017 | Identical |