BS ISO TR 11974:1997
Withdrawn
Measurement of liquid flow in open channels. Electromagnetic current meters
Hardcopy , PDF
English
10-15-1998
11-01-2007
1 Scope
2 Normative reference
3 Definitions
4 Principle of operation
5 Electromagnetic current meters
6 Operational aspects
7 Calibration
8 Maintenance
9 Transport and storage
10 Log book
Specifies the operational requirements, construction, calibration and maintenance aspects of solid-state electromagnetic current meters for measurement of flow velocity of electrically conducting liquids, including water.
| Committee |
CPI/113
|
| DevelopmentNote |
Supersedes 98/120287 DC. (06/2005) This standard will be withdrawn on 01/11/2007. (10/2007)
|
| DocumentType |
Standard
|
| Pages |
14
|
| PublisherName |
British Standards Institution
|
| Status |
Withdrawn
|
| Supersedes |
| Standards | Relationship |
| ISO/TR 11974:1997 | Identical |
| ISO 748:2007 | Hydrometry — Measurement of liquid flow in open channels using current-meters or floats |
| ISO/TR 9824-2:1990 | Measurement of free surface flow in closed conduits — Part 2: Equipment |
| ISO/TR 9824-1:1990 | Measurement of free surface flow in closed conduits — Part 1: Methods |
| ISO 2537:2007 | Hydrometry — Rotating-element current-meters |
| ISO 772:1996 | Hydrometric determinations — Vocabulary and symbols |
| ISO 3455:2007 | Hydrometry — Calibration of current-meters in straight open tanks |