CEI EN 50131-2-4 : 2008
Withdrawn
ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-4: REQUIREMENTS FOR COMBINED PASSIVE INFRARED AND MICROWAVE DETECTORS
Hardcopy , PDF
English - Italian
01-01-2008
07-01-2021
INTRODUCTION
1 Scope
2 Normative references
3 Definitions and abbreviations
4 Functional requirements
5 Marking, identification and documentation
6 Testing
Annex A (normative) - Dimensions & requirements
of the standardised test magnets
Annex B (normative) - General testing matrix
Annex C (normative) - Walk test diagrams
Annex D (normative) - Procedure for calculation
of the average temperature difference
between the standard target and the background
Annex E (informative) - Basic detection target for
the basic test of detection capability
Annex F (informative) - Equipment for walk
test velocity control
Annex G (informative) - Immunity to visible and
near Infrared radiation - Notes on
calibration of the light source
Annex I (informative) - Example list of small tools
Annex J (informative) - Test for resistance to
re-orientation of adjustable mountings
Gives the security Grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5).
| Committee |
CT 79
|
| DevelopmentNote |
Classificazione CEI 79-54. Supersedes CEI CLC/TS 50131-2-4. (10/2008) An interpretation sheet 2015 exists for CEI EN 50131-2-4, See CEI EN 50131-2-4/IS1. (12/2015)
|
| DocumentType |
Standard
|
| Pages |
82
|
| PublisherName |
Comitato Elettrotecnico Italiano
|
| Status |
Withdrawn
|
| Supersedes |
| Standards | Relationship |
| EN 50131-2-4:2008 | Identical |
| CEI 79-3 : 2012 | ALARM SYSTEMS - PARTICULAR REQUIREMENTS FOR INTRUSION AND HOLD-UP INSTALLATIONS |
| IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
| EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
| IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
| CEI 70-1 : 1980 COR 1993 | |
| EN 50131-1:2006/A2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
| EN 50131-6:2017 | Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies |
| EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
| EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
| IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
| EN 50130-5:2011 | Alarm systems - Part 5: Environmental test methods |