CEN ISO/TS 16775:2014
Withdrawn
View Superseded by
Packaging for terminally sterilized medical devices - Guidance on the application of ISO 11607-1 and ISO 11607-2 (ISO/TS 16775:2014)
05-21-2014
03-11-2023
Foreword
Introduction
1 Scope
2 Terms and definitions
3 Guidance for health care facilities
4 Guidance for industry
Annex A (informative) - Selection, evaluation
and testing of packaging materials and
sterile barrier systems - Guidance for
industry and health care facilities
Annex B (informative) - Sterilization
considerations - Guidance for industry
and health care facilities
Annex C (informative) - Examples of
wrapping methods - Guidance for health
care facilities
Annex D (informative) - Validation plan
documents - Guidance for health care facilities
Annex E (informative) - Installation qualification
documentation - Guidance for health care facilities
Annex F (informative) - Operational qualification
documentation - Guidance for health care facilities
Annex G (informative) - Performance qualification
documentation - Guidance for health care facilities
Annex H (informative) - Addressing worst-case
requirements - Guidance for industry and health
care facilities
Annex I (informative) - Generating a final packaging
system validation protocol - Guidance for industry
Annex J (informative) - Design inputs - Medical device
attributes - Guidance for industry
Annex K (informative) - Risk analysis tools - Guidance
for industry and health care facilities
Annex L (informative) - Considerations for sampling
plans - Guidance for health care facilities
Annex M (informative) - Stability testing
(ISO 11607-1:2006, 6.4) - Guidance for industry
Annex N (informative) - Use of the Internet - Guidance for
industry and health care facilities
Annex O (informative) - Test method validation -
Guidance for industry
Annex P (informative) - Use of contract packagers -
Guidance for industry and health care facilities
Annex Q (informative) - Guidance on establishing process
parameters - Guidance for industry
Annex R (informative) - Investigation failure -
Guidance for industry and health care facilities
Annex S (informative) - Packaging manufacturing
process and packaging system design feasibility
evaluation - Guidance for industry
Bibliography
ISO/TS 16775:2014 provides guidance for the application of the requirements contained in ISO 11607‑1 and ISO 11607‑2. It does not add to, or otherwise change, the requirements of ISO 11607‑1 and/or ISO 11607‑2. It is an informative document, not normative, and does not include requirements to be used as basis of regulatory inspection or certification assessment activities.The guidance can be used to better understand the requirements of ISO 11607‑1 and/or ISO 11607‑2 and illustrates some of the variety of methods and approaches available for meeting the requirements of those International Standards. It is not required to be used to demonstrate compliance with them.Guidelines are given for evaluation, selection and use of packaging materials, preformed sterile barrier systems, sterile barrier systems and packaging systems. Guidance on validation requirements for forming, sealing and assembly processes is also given.ISO/TS 16775:2014 provides information for health care facilities and for the medical devices industry. It does not provide guidance for applications of packaging materials and systems after their opening. In the use of packaging for other purposes such as a "sterile field" or transport of contaminated items, other regulatory standards will apply.
| Committee |
CEN/TC 102
|
| DocumentType |
Technical Specification
|
| PublisherName |
Comite Europeen de Normalisation
|
| Status |
Withdrawn
|
| SupersededBy |
| Standards | Relationship |
| S.R. CEN ISO/TS 16775:2014 | Identical |
| ISO/TS 16775:2014 | Identical |
| DIN CEN ISO/TS 16775;DIN SPEC 58997:2014-10 | Identical |
| PD CEN ISO/TS 16775:2014 | Identical |
| NEN NPR CEN ISO/TS 16775 : 2014 | Identical |