• Shopping Cart
    There are no items in your cart
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

CISPR 16-1-1:2015

Superseded

Superseded

View Superseded by

Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

09-22-2015

Superseded date

12-31-2021

Superseded by

CISPR 16-1-1:2019

US$578.00
Excluding Tax where applicable
Summarise this standard

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Quasi-peak measuring receivers for the
  frequency range 9 kHz to 1000 MHz
5 Measuring receivers with peak detector for
  the frequency range 9 kHz to 18 GHz
6 Measuring receivers with average detector
  for the frequency range 9 kHz to 18 GHz
7 Measuring receivers with rms-average
  detector for the frequency range 9 kHz to
  18 GHz
8 Measuring receivers for the frequency
  range 1 GHz to 18 GHz with amplitude
  probability distribution (APD) measuring
  function
9 Disturbance analyzers
Annex A (normative) - Determination of response
        to repeated pulses of quasi-peak and
        rms-average measuring receivers
Annex B (normative) - Determination of pulse
        generator spectrum
Annex C (normative) - Accurate measurements
        of the output of nanosecond pulse
        generators
Annex D (normative) - Influence of the quasi-peak
        measuring receiver characteristics
        on its pulse response
Annex E (normative) - Response of average and
        peak measuring receivers
Annex F (normative) - Performance check of the
        exceptions from the definitions of a
        click according to 4.2.3 of CISPR 14-1:2005
Annex G (informative) - Rationale for the
        specifications of the APD measuring function
Annex H (informative) - Characteristics of a quasi-peak
        measuring receiver
Annex I (informative) - Example of EMI receiver
        and swept spectrum analyzer architecture
Annex J (normative) - Requirements when using an
        external preamplifier with a measuring receiver
Annex K (normative) - Calibration requirements for
        measuring receivers
Bibliography

CISPR 16-1-1:2015 specifies the characteristics and performance of equipment for the measurement of radio disturbance in the frequency range 9 kHz to 18 GHz. In addition, requirements are provided for specialized equipment for discontinuous disturbance measurements. This fourth edition cancels and replaces the third edition published in 2010, Amendment 1:2010 and Amendment 2:2014. This edition constitutes a technical revision.
The contents of the interpretation sheet 1 of April 2018 have been included in this copy.

Committee
CISPR/CIS/A
DevelopmentNote
Together with CISPR 16-1-2, CISPR 16-1-3, CISPR 16-1-5 and CISPR 16-1-4, supersedes CISPR 16-1. (11/2003) Stability date: 2018. (09/2015)
DocumentType
Standard
Pages
207
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

⚠

A newer version of this standard is available.

View Current Edition
US$578.00
Excluding Tax where applicable