CLC/TR 62271-303:2009
Withdrawn
View Superseded by
High-voltage switchgear and controlgear - Part 303: Use and handling of sulphur hexafluoride (SF6)
09-03-2009
03-12-2025
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Storage and transportation of SF[6]
5 Safety and first aid
6 Training and certification
7 SF[6] handling during installation and commissioning
8 SF[6] handling during normal service life
9 SF[6] recovering and reclaiming during maintenance
10 Dismantling of SF[6] electric power equipment at
the end-of-life
11 Description of SF[6] handling equipment
Annex A (informative) - Sulphur hexafluoride
Annex B (informative) - Environmental effects of SF[6]
Annex C (informative) - SF[6] by-products
Annex D (informative) - Potential effects on health of SF[6]
by-products
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding
European publications
Describes the procedures for safe and environmental compatible handling of SF[6] during installation, commissioning, normal and abnormal operations, disposal at the end-of-life of high-voltage switchgear and controlgear.
| Committee |
CLC/TC 17AC
|
| DocumentType |
Technical Report
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Withdrawn
|
| SupersededBy |
| Standards | Relationship |
| NEN NPR CLC IEC/TR 62271-303 : 2009 | Identical |
| PD CLC/TR 62271-303:2009 | Identical |
| CEI CLC/TR 62271-303 : 2011 | Identical |
| DIN V 62271-303 : 2010 | Identical |
| IEC TR 62271-303:2008 | Identical |
| VDE V 0671-303 : 2010 | Identical |
| S.R. CLC/TR 62271-303:2009 | Identical |
| CEI EN 62271-204 : 2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGES ABOVE 52 KV |
| BS EN 62271-203:2012 | High-voltage switchgear and controlgear Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
| BS EN 62271-200:2012 | High-voltage switchgear and controlgear AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
| EN 62271-200:2012/AC:2015 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011) |
| EN 61936-1 : 2010 AMD 1 2014 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014) |
| I.S. EN 61936-1:2010 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
| BS EN 61936-1 : 2010 | POWER INSTALLATIONS EXCEEDING 1 KV A.C - PART 1: COMMON RULES |
| EN 62271-204:2011 | High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV |
| CEI EN 62271-203 : 2013 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV |
| I.S. EN 62271-204:2011 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGE ABOVE 52 KV (IEC 62271-204:2011 (EQV)) |
| BS EN 62271-204:2011 | High-voltage switchgear and controlgear Rigid gas-insulated transmission lines for rated voltage above 52 kV |
| I.S. EN 62271-203:2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-203:2011 (EQV)) |
| EN 62271-203:2012 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
| UNE-EN 62271-203:2013 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
| UNE-EN 62271-204:2012 | High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV |
| UNE-EN 61936-1:2012 | Power installations exceeding 1 kV a.c. - Part 1: Common rules |
| IEC 60480:2004 | Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use |
| IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
| EN 60376:2005 | Specification of technical grade sulfur hexafluoride (SF6) for use in electrical equipment |
| IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
| IEC 62271-201:2014 | High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
| EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
| IEC 60050-601:1985 | International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General |
| IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
| EN 60480:2004 | Guidelines for the checking and treatment of sulphur hexafluoride (SF6) taken from electrical equipment and specification for its re-use |
| IEC 60376:2005 | Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment |
| IEC 62271-203:2011 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
| IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
| IEC 60695-7-1:2010 | Fire hazard testing - Part 7-1: Toxicity of fire effluent - General guidance |
| ISO 14040:2006 | Environmental management — Life cycle assessment — Principles and framework |