DD ENV 1401-3:2001
Withdrawn
Plastics piping systems for non-pressure underground drainage and sewerage. Unplasticized poly(vinylchloride) (PVC-U) Guidance for installation
Hardcopy , PDF
English
08-15-2001
03-24-2021
Foreword
1 Scope
2 Normative references
3 Choice of stiffness (SN) series
3.1 General
3.2 Pipes
3.3 Fittings
3.4 Application area code D
4 Storage in sunlight
5 Handling and installation at low temperature
6 Push-fit joints (elastomeric sealings)
7 Solvent cement joints
8 Maximum deviation from straightness
9 Connection to rigid structures
10 Repairs
11 Connection to existing pipes
12 Testing on site
Gives a material-specific set of guidelines for the installation of piping systems made of unplasticized poly(vinyl chloride) (PVC-U) in the field of non-pressure underground drainage and sewerage.
| Committee |
PRI/88
|
| DevelopmentNote |
Supersedes 98/124336 DC. (05/2005)
|
| DocumentType |
Standard
|
| Pages |
12
|
| PublisherName |
British Standards Institution
|
| Status |
Withdrawn
|
| Supersedes |
| Standards | Relationship |
| ENV 1401-3:2001 | Identical |
| I.S. ENV 1401-3:2001 | Equivalent |
| DIN V ENV 1401-3:2001-10 | Equivalent |
| EN 1295-1:1997 | Structural design of buried pipelines under various conditions of loading - Part 1: General requirements |
| EN ISO 9967:2016 | Thermoplastics pipes - Determination of creep ratio (ISO 9967:2016) |
| EN 1401-1:2009 | Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U) - Part 1: Specifications for pipes, fittings and the system |
| ISO/TR 7073:1988 | Recommended techniques for the installation of unplasticized poly(vinyl chloride) (PVC-U) buried drains and sewers |
| EN 1610:2015 | Construction and testing of drains and sewers |