DIN EN 357:2005-02
Withdrawn
GLASS IN BUILDING - FIRE-RESISTANT GLAZED ELEMENTS WITH TRANSPARENT OR TRANSLUCENT GLASS PRODUCTS - CLASSIFICATION OF FIRE RESISTANCE
Hardcopy , PDF
English
01-01-2005
03-07-2021
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Glass products
5 Classification
5.1 General
5.2 Loadbearing separating fire resistant glazed elements
5.3 Non-loadbearing separating fire resistant glazed elements
6 Requirements and test methods
6.1 General requirements and test methods
6.2 Fire resistance requirements and tests
Annex A (informative) Typical structures commonly available in
the relevant fire resistant glazed elements
Bibliography
Specifies a classification of transparent or translucent glass products for use in appropriate glaze elements intended specially to provide fire resistance.
| DocumentType |
Standard
|
| Pages |
12
|
| PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
| Status |
Withdrawn
|
| Standards | Relationship |
| NS EN 357 : 2ED 2004 | Identical |
| NEN EN 357 : 2004 | Identical |
| NBN EN 357 : 2005 | Identical |
| I.S. EN 357:2004 | Identical |
| NF EN 357 : 2005 | Identical |
| BS EN 357:2004 | Identical |
| EN 357:2004 | Identical |
| UNE-EN 357:2005 | Equivalent |
| EN 572-3:2012 | Glass in building - Basic soda lime silicate glass products - Part 3: Polished wired glass |
| EN 12337-1:2000 | Glass in building - Chemically strengthened soda lime silicate glass - Part 1: Definition and description |
| EN 13024-1:2011 | Glass in building - Thermally toughened borosilicate safety glass - Part 1: Definition and description |
| EN 1364-3:2014 | Fire resistance tests for non-loadbearing elements - Part 3: Curtain walling - Full configuration (complete assembly) |
| EN 1748-2-1:2004 | Glass in building - Special basic products - Glass ceramics - Part 2-1 Definitions and general physical and mechanical properties |
| PREN 14179-1 : DRAFT 2014 | GLASS IN BUILDING - HEAT SOAKED THERMALLY TOUGHENED SODA LIME SILICATE SAFETY GLASS - PART 1: DEFINITION AND DESCRIPTION |
| EN 1364-1:1999 | Fire resistance tests for non-loadbearing elements - Part 1: Walls |
| EN 572-7:2012 | Glass in building - Basic soda lime silicate glass products - Part 7: Wired or unwired channel shaped glass |
| EN 1096-1:2012 | Glass in building - Coated glass - Part 1: Definitions and classification |
| EN ISO 12543-2:2011 | Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:2011) |
| ISO 12543-3:2011 | Glass in building — Laminated glass and laminated safety glass — Part 3: Laminated glass |
| EN 1863-1:2011 | Glass in building - Heat strengthened soda lime silicate glass - Part 1: Definition and description |
| EN 14178-1:2004 | Glass in building - Basic alkaline earth silicate glass products - Part 1: Float glass |
| EN ISO 12543-3:2011 | Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass (ISO 12543-3:2011) |
| EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
| EN 572-6:2012 | Glass in building - Basic soda lime silicate glass products - Part 6: Wired patterned glass |
| EN 572-2:2012 | Glass in building - Basic soda lime silicate glass products - Part 2: Float glass |
| EN 1279-3:2002 | Glass in building - Insulating glass units - Part 3: Long term test method and requirements for gas leakage rate and for gas concentration tolerances |
| EN 12150-1:2015 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 1: Definition and description |
| EN 1279-4:2002 | Glass in building - Insulating glass units - Part 4: Methods of test for the physical attributes of edge seals |
| ISO 834:1975 | Fire-resistance tests — Elements of building construction |
| EN 1748-1-1:2004 | Glass in building - Special basic products -Borosilicate glasses - Part 1-1: Definition and general physical and mechanical properties |
| EN 572-4:2012 | Glass in building - Basic soda lime silicate glass products - Part 4: Drawn sheet glass |
| ISO 12543-1:2011 | Glass in building — Laminated glass and laminated safety glass — Part 1: Definitions and description of component parts |
| EN 1279-2:2002 | Glass in building - Insulating glass units - Part 2: Long term test method and requirements for moisture penetration |
| EN 1363-1:2012 | Fire resistance tests - Part 1: General Requirements |
| ISO 12543-4:2011 | Glass in building — Laminated glass and laminated safety glass — Part 4: Test methods for durability |
| EN ISO 12543-4:2011 | Glass in building - Laminated glass and laminated safety glass - Part 4: Test methods for durability (ISO 12543-4:2011) |
| ISO 12543-6:2011 | Glass in building — Laminated glass and laminated safety glass — Part 6: Appearance |
| EN 572-5:2012 | Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass |
| EN 1051-1:2003 | Glass in building - Glass blocks and glass pavers - Part 1: Definitions and description |
| EN 1363-2:1999 | Fire resistance tests - Part 2: Alternative and additional procedures |
| EN ISO 12543-5:2011 | Glass in building - Laminated glass and laminated safety glass - Part 5: Dimensions and edge finishing (ISO 12543-5:2011) |
| EN 1096-3:2012 | Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings |
| ISO 12543-5:2011 | Glass in building — Laminated glass and laminated safety glass — Part 5: Dimensions and edge finishing |
| EN ISO 12543-1:2011 | Glass in building - Laminated glass and laminated safety glass - Part 1: Definitions and description of component parts (ISO 12543-1:2011) |
| EN 1365-2:2014 | Fire resistance tests for loadbearing elements - Part 2: Floors and roofs |
| EN 1096-2:2012 | Glass in building - Coated glass - Part 2: Requirements and test methods for class A, B and S coatings |