DIN EN 61158-2:2015-02
Current
INDUSTRIAL COMMUNICATION NETWORKS - FIELDBUS SPECIFICATIONS - PART 2: PHYSICAL LAYER SPECIFICATION AND SERVICE DEFINITION (IEC 61158-2:2014)
Hardcopy , PDF
German
02-01-2015
0 Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 DLL - PhL interface
6 Systems management - PhL interface
7 DCE independent sublayer (DIS)
8 DTE - DCE interface and MIS-specific functions
9 Medium dependent sublayer (MDS)
10 MDS - MAU interface
11 Types 1 and 7: Medium attachment unit:
voltage mode, linear-bus-topology 150 Omega
twisted-pair wire medium
12 Types 1 and 3: Medium attachment unit:
31,25 kbit/s, voltage-mode with low-power
option, bus- and tree-topology, 100 Omega wire
medium
13 Type 1: Medium attachment unit: current
mode, twisted-pair wire medium
14 Type 1: Medium attachment unit: current
mode (1 A), twisted-pair wire medium
15 Types 1 and 7: Medium attachment unit:
dual-fiber optical media
16 Type 1: Medium attachment unit: 31,25
kbit/s, single-fiber optical medium
17 Void
18 Type 2: Medium attachment unit: 5 Mbit/s,
voltage-mode, coaxial wire medium
19 Type 2: Medium attachment unit: 5 Mbit/s,
optical medium
20 Type 2: Medium attachment unit: network
access port (NAP)
21 Type 3: Medium attachment unit: synchronous
transmission, 31,25 kbit/s, voltage mode,
wire medium
22 Type 3: Medium attachment unit: asynchronous
transmission, wire medium
23 Type 3: Medium attachment unit: asynchronous
transmission, optical medium
24 Type 4: Medium attachment unit: RS-485
25 Void
26 Void
27 Type 8: Medium attachment unit: twisted-pair
wire medium
28 Type 8: Medium attachment unit: optical media
29 Type 12: Medium attachment unit: electrical
medium
30 Type 16: Medium attachment unit: optical fiber
medium at 2, 4, 8 and 16 Mbit/s
31 Type 18: Medium attachment unit: basic medium
32 Type 18: Medium attachment unit: powered
medium
33 Type 24: Medium attachment unit: twisted-pair
wire medium
34 Type 20: Medium attachment unit: FSK medium
Annex A (normative) - Type 1: Connector
specification
Annex B (informative) - Types 1 and 3: Cable
specifications and trunk and spur lengths for
the 31,25 kbit/s voltage-mode MAU
Annex C (informative) - Types 1 and 7: Optical
passive stars
Annex D (informative) - Types 1 and 7: Star topology
Annex E (informative) - Type 1: Alternate fibers
Annex F (normative) - Type 2: Connector specification
Annex G (normative) - Type 2: Repeater machine sublayers
(RM, RRM) and redundant PhLs
Annex H (informative) - Type 2: Reference design examples
Annex I (normative) - Type 3: Connector specification
Annex J (normative) - Type 3: Redundancy of PhL and
medium
Annex K (normative) - Type 3: Optical network topology
Annex L (informative) - Type 3: Reference design examples
for asynchronous transmission, wire medium,
intrinsically safe
Annex M (normative) - Type 8: Connector specification
Annex N (normative) - Type 16: Connector specification
Annex O (normative) - Type 16: Optical network topology
Annex P (informative) - Type 16: Reference design example
Annex Q (normative) - Type 18: Connector specification
Annex R (normative) - Type 18: Media cable specifications
Annex S (normative) - Type 24: Connector specification
Annex T (informative) - Type 20: Network topology, cable
characteristics and lengths, power distribution through
barriers, and shielding and grounding
Bibliography
Annex ZA (normative)
Defines the requirements for fieldbus component parts.
| DevelopmentNote |
Available on CD ROM. Supersedes DIN EN 50170, DIN EN 50170-1, DIN EN 50170-2, DIN EN 50170-3, DIN EN 50254 and DIN IEC 61158-2. (05/2005) Supersedes DIN EN 61491. (11/2008)
|
| DocumentType |
Standard
|
| Pages |
508
|
| PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| IEC 61158-2:2014 | Identical |
| BS EN 61158-2:2014 | Identical |
| EN 61158-2:2014 | Identical |
| NF EN 61158-2 : 2015 | Identical |
| I.S. EN 61158-2:2014 | Identical |
| NBN EN 61158-2 : 2014 | Identical |