EN 1279-2:2002
Superseded
View Superseded by
Glass in building - Insulating glass units - Part 2: Long term test method and requirements for moisture penetration
11-13-2002
02-28-2019
Foreword
1 Scope
2 Normative references
3 Terms and definitions, abbreviations and symbols
3.1 Terms and definitions
3.2 Abbreviations
3.3 Symbols
4 Requirements
4.1 Moisture penetration index
4.2 Edge seal strength
4.3 Gas leakage rate
5 Method of test
5.1 Principle
5.2 Climate conditions in cabinet
5.3 Number, description and selection of the test
specimens
5.4 Procedure
6 Methods of measurement
6.1 Measurement of dew point temperature
6.2 Measurement of moisture content
6.2.1 General
6.2.2 Moisture content of desiccant in bulk
6.2.3 Moisture content of desiccant incorporated
in organic spacer
6.2.4 Moisture content in insulating glass units
without desiccant
7 Test report
Annex A (normative) - Reference method for dew point
temperature measurement
A.1 General
A.2 Apparatus and materials
A.3 Procedure
Annex B (normative) - Moisture content measurement
according to the 950 degree C drying method
B.1 Applicability
B.2 Apparatus, materials and preparatory work
B.3 Initial and final moisture content
B.4 Standard moisture adsorption capacity
Annex C (normative) - Moisture content measurement
according to the Karl Fischer method
C.1 Applicability
C.2 Apparatus, materials and preparatory work
C.3 Initial and final moisture content
C.4 Standard moisture adsorption capacity
Annex D (normative) - Establishing the standard moisture
adsorption capacity of desiccants
D.1 General
D.2 Appropriate information
D.3 Generally accepted values for desiccant in bulk
D.4 Desiccant manufacturing
Bibliography
This draft European Standard is the product standard fo insulating glass units, which defines insulating glass units, and ensures by means of an adequate evaluation of conformity to this standard that: - energy savings are made because the U-value and solar factor do not change significantly; - health because sound reduction and vision do not change significantly; - safety is provided because mechanical resistance does not change significantly.
| Committee |
CEN/TC 129
|
| DocumentType |
Standard
|
| PublisherName |
Comite Europeen de Normalisation
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| NEN EN 1279-2 : 2002 | Identical |
| I.S. EN 1279-2:2002 | Identical |
| I.S. EN 1279-2:2018 | Identical |
| NBN EN 1279-2 : 2003 | Identical |
| DIN EN 1279-2:2018-10 | Identical |
| BS EN 1279-2:2018 | Identical |
| ÖNORM EN 1279-2:2003 05 01 | Identical |
| DIN EN 1279-2:2015-08 (Draft) | Identical |
| PN EN 1279-2 : 2004 | Identical |
| NF EN 1279-2 : 2003 | Identical |
| NS EN 1279-2 : 1ED 2003 | Identical |
| BS EN 1279-2:2002 | Identical |
| NEN EN 1279-2:2018 | Identical |
| DS/EN 1279-2:2018 | Identical |
| UNE-EN 1279-2:2003 | Identical |