• Shopping Cart
    There are no items in your cart

EN 14620-1:2006

Withdrawn

Withdrawn

Design and manufacture of site built, vertical, cylindrical, flat-bottomed steel tanks for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -165 °C - Part 1: General

Published date

09-13-2006

Withdrawn date

03-31-2007

Sorry this product is not available in your region.
Summarise this standard

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Concept selection
  4.1 Types of tank
  4.2 Risk assessment
5 Quality assurance and quality control
6 Health, safety and environment plan
7 General design considerations
  7.1 General
  7.2 Protection systems
  7.3 Actions (loadings)
8 Inspection and maintenance
Annex A (informative) Physical properties of gases
Annex B (normative) Design information
Annex C (normative) Seismic analysis
Annex D (informative) Tank heating system
Bibliography

This European Standard is a specification for vertical, cylindrical tanks, built on site, above ground and of which the primary liquid container is made of steel. The secondary container, if applicable, may be of steel or of concrete or a combination of both. An inner tank made only of pre-stressed concrete is excluded from the scope of this European Standard.This European Standard specifies principles and application rules for the structural design of the “containment” during construction, testing, commissioning, operation (accidental included), and decommissioning. It does not address the requirements for ancillary equipment such as pumps, pumpwells, valves, piping, instrumentation, staircases etc. unless they can affect the structural design of the tank.This European Standard applies to storage tanks designed to store products, having an atmospheric boiling point below ambient temperature, in a dual phase, i.e. liquid and vapour. The equilibrium between liquid and vapour phases being maintained by cooling down the product to a temperature equal to, or just below, its atmospheric boiling point in combination with a slight overpressure in the storage tank.The maximum design pressure of the tanks covered by this European Standard is limited to 500 mbar. For higher pressures, reference can be made to EN 13445, Parts 1 to 5.The operating range of the gasses to be stored is between 0 °C and –165 °C. The tanks for the storage of liquefied oxygen, nitrogen and argon are excluded.The tanks are used to store large volumes of hydrocarbon products and ammonia with low temperature boiling points, generally called “Refrigerated Liquefied Gases” (RLG’s). Typical products stored in the tanks are: methane, ethane, propane, butane, ethylene, propylene, butadiene (this range includes the LNG’s and LPG’s).NOTEProperties of the gases are given in Annex A.The requirements of this European Standard cannot cover all details of design and construction because of the variet

Committee
CEN/TC 265
DevelopmentNote
Supersedes PREN 14620-1. (12/2007)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn
Supersedes

Sorry this product is not available in your region.