EN 15502-2-2:2014

Withdrawn

Withdrawn

Gas-fired central heating boilers - Part 2-2: Specific standard for type B1 appliances

Published date

07-30-2014

Withdrawn date

07-31-2017

Sorry this product is not available in your region.
Summarise this standard

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Classification
5 Construction
6 Electrical safety
7 Controls
8 Operational requirements
9 Useful efficiencies
10 Electric auxiliary energy
11 Risk assessment
12 Marking and instructions
101 Figures
102 Listing of tables and numbers
103 Annexes
Annex I (informative) - Compilation of the test
        conditions for the various gas families
Annex V (informative) - Standards replaced by this
        standard in combination with EN 15502-1
Annex ZA (informative) - Clauses of this European
         Standard addressing essential requirements
         or provisions of EU Directive 2009/142/EC,
         'Directive relating to appliances Burning
         gaseous fuels (codified version)' (GAD)
Annex ZB (informative) - Clauses of this European standard
         addressing the methods for the verification of the
         efficiency of the EU Directive 92/42/EEC, relating
         to the efficiency of new hot boilers with an output
         of 4 kW - 400 kW
Bibliography

This European Standard specifies, the requirements and test methods concerning, in particular the construction, safety, fitness for purpose, and rational use of energy, as well as the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners and are hereafter referred to as boilers.Where the word boiler is used, this is to be read as the boiler including its connecting ducts, ducts and terminals, if any.This European Standard covers gas-fired central heating boilers type B11, B11BS, B12, B12BS, B13, B13BS according to the classification in CEN/TR 1749:2009:a)that have a nominal heat input (on the basis of net calorific value) not exceeding 70 kW;b)that use one or more combustible gases of the three gas families at the pressures stated in EN 437;c)where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;d)where the maximum operating pressure in the water circuit does not exceed 6 bar;e)which are declared in the technical instructions to be either a low temperature boiler or a standard boiler. If no declaration is given the boiler is to be considered a standard boiler;f)which are intended to be installed either indoors or in a partially protected place;g)which are either not intended to produce hot water, or are intended to produce hot water either by the instantaneous or storage principle, the whole being marketed as a single unit.h)which are designed for either sealed water systems or for open water systems.This European Standard is to be used in conjunction with the General Requirements Standard EN 15502 1.For applications within the scope of the PED further requirements may be necessary (e.g. situations where the maximum allowable temperature exceeds 110 °C, or where volume times maximum allowable pressure is over 50 bar x litres).This standard provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard, the risk associated with this alternative construction shall be assessed.An example of an assessment methodology, based upon risk assessment and which covers the essential requirements of the Gas Appliance Directive, is given in Clause 11.This standard does not cover all the requirements for:i)appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex DD of EN 15502 2 1:2012);j)appliances using flue dampers;k)appliances that have a nominal heat input (on the basis of net calorific value) exceeding 70 kW;l)appliances of the types A, B14, B2, B3, B4, B5 and C;m)appliances intended to be connected to a (common) flue having mechanical extraction;n)appliances with gas/air ratio control;o)modular boilers;p)boilers which can give rise to condensation under certain circumstances;q)boilers intended to be installed in a room with a foreseeable negative pressure relative to the pressure in the flue system.NOTENegative pressure relative to the pressure in the flue system can for example be caused by mechanical or thermal ventilation in airtight buildings.

Committee
CEN/TC 109
DevelopmentNote
Supersedes EN 15417, EN 297, EN 625 & EN 677 which remains current until 2017. Supersedes PREN 15502-2-2. To be used in conjunction with EN 15502-1. (08/2014)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn