EN 2794-004:2014
Current
Aerospace series - Circuit breakers, single-pole, temperature compensated, rated currents 20 A to 50 A - Part 004: UNC thread terminals - Product standard
01-22-2014
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Dimensions and mass
5 Characteristics
6 Designation
7 Rated current code
8 Delivery hardware code
9 Marking
10 Technical specification
This European Standard specifies the characteristics of single-pole circuit breakers, temperature compensated with a rated current from 20 A to 25 A, used in aircraft on-board circuits at a temperature between - 55 °C and 125 °C and at an altitude of 15 000 m max.These circuit breakers are operated by a push-pull type single push button (actuator), with delayed action "trip-free" tripping.They will continue to function up to the short-circuit current.