EN 50264-2-2:2008
Current
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
06-27-2008
Introduction
1 Scope
2 Normative references
3 Definitions
4 Rated voltage
5 Marking and identification
5.1 Marking of cable
5.2 Core identification
5.3 Sheath
6 Construction of cables
6.1 General
6.2 Conductor
6.3 Insulation system
6.4 Laying up of cores and fillers
6.5 Metallic screen
6.6 Sheath
6.7 Construction
7 Tests
7.1 Definitions relating to tests
7.2 Conductor resistance
7.3 Voltage test
7.4 Insulation resistance
7.5 Dielectric strength on sample
7.6 Spark test
7.7 Surface resistance
7.8 Ageing test
7.9 Hot set test
7.10 Compatibility
7.11 Water absorption of sheath
7.12 Ozone resistance
7.13 Mineral oil resistance
7.14 Fuel resistance
7.15 Acid and alkali resistance
7.16 Bending test at low temperature (cores or cables
with OD <= 12,5 mm)
7.17 Cold elongation test (cores or cables with OD > 12,5 mm)
7.18 Impact test at low temperature
7.19 Reaction to fire - Cable
7.20 Reaction to fire - Components
Annex A (normative) - Code designation
Bibliography
EN 50264-2-2 specifies requirements for, and constructions and dimensions of, multicore cables of the following types and voltage ratings: • 300/500 V screened or unscreened (1 mm², 1,5 mm² and 2,5 mm², number of cores from 2 to 40); • 0,6/1 kV screened or unscreened (1,5 mm² to 50 mm², 2, 3 and 4 cores). NOTE Not all conductor sizes or number of cores are specified for every type. All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-2-2 should be read in conjunction with Part 1 “General requirements”.
| Committee |
CLC/TC 20
|
| DevelopmentNote |
Supersedes EN 50264-3. To be read in conjunction with EN 50264-1. (08/2008)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| NBN EN 50264-2-2 : 2009 | Identical |
| NEN EN 50264-2-2 : 2008 | Identical |
| DIN EN 50264-2-2:2009-03 | Identical |
| VDE 0260-264-2-2:2009-03 | Identical |
| NF EN 50264-2-2 : 2008 | Identical |
| I.S. EN 50264-2-2:2008 | Identical |
| PN EN 50264-2-2 : 2008 | Identical |
| CEI EN 50264-2-2 : 2009 | Identical |
| BS EN 50264-2-2:2008 | Identical |
| UNE-EN 50264-2-2:2008 | Identical |
| UNE-EN 50264-2-2:2010 | Identical |