EN 50270:2015
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen
11-25-2019
01-16-2015
1 Scope
2 Normative references
3 Terms and Definitions
4 EMC test plan
5 Immunity tests
6 Emission tests
7 Test report
8 Modifications
Annex ZZ (informative) - Coverage of Essential
Requirements of EU Directives
Bibliography
This European Standard specifies requirements for the electromagnetic compatibility (EMC) for electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen which are subject to the performance standards for gas detection apparatus, for example EN 45544 (all parts), EN 50104, EN 50194 (all parts), EN 50291, EN 50379 (all parts), EN 50543, EN 50545, EN 60079-29-1 or EN 60079-29-4.NOTEFor the purpose of this standard the word ‘toxic’ covers ‘very toxic’, ‘toxic’, ‘harmful’, ‘corrosive‘, ‘irritating‘, ‘sensitising‘, ‘carcinogenic‘, ‘mutagenic‘ and ‘teratogenic‘.This European Standard applies to apparatus intended for use in residential, commercial and light-industrial environments as well as to apparatus intended for use in industrial environments. The apparatus may be AC-, DC- or battery powered.This European Standard is also applicable to apparatus which is intended for use in hazardous areas which may contain explosive or potentially explosive atmospheres. It covers only normal operation and does not cover safety requirements related to EMC phenomena.This standard is a product standard which is based on the product family standard EN 61326-1. This product standard takes precedence over the product family standard and over generic standards.This standard applies to electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen that include functions specified by the manufacturer as being safety functions and can include functions specified as not being safety functions.All performance standards for the detection and measurement of combustible gases, toxic gases or oxygen include the minimum requirements for functional safety specified in EN 50271. There are also gas detectors and gas detection systems which are intended to be used with safety integrity levels SIL 1 to SIL 3 according to EN 50402 and EN 61508. For functional safety in industrial applications, this standard has taken into account those aspects of EN 61326–3–2 relating to the measuring and warning function of the apparatus defined as safety function.Apparatus of type 1 where the manufacturer claims a safety integrity level should be considered as type 2 apparatus with regard to immunity requirements.This standard specifies requirements for immunity tests in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges, and also for emission tests. The test requirements are specified for each port considered.Apparatus falling within the scope of this European Standard is classified as follows by the following types.Type 1: apparatus intended for use in residential, commercial and light-industrial environments, as described in EN 61000-6-1 and EN 61000-6-3.Type 2: apparatus intended for use in industrial environments, as described in EN 61000-6-2 and EN 61000-6-4.This European Standard does not apply to any of the following:apparatus intended for the detection of dusts or mists in air;scientific or laboratory based apparatus used only for analysis or measurement;apparatus used exclusively for process measurement purposes;apparatus for medical purposes;apparatus used for breath alcohol measurementapparatus intended for the direct measurement of automotive exhaust gases.
Committee |
CLC/TC 31
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NF EN 50270 : 2015 | Identical |
NBN EN 50270 : 2015 COR 2016 | Identical |
NEN EN 50270 : 2015 C1 2016 | Identical |
I.S. EN 50270:2015 | Identical |
PN EN 50270 : 2015 AC 2016 | Identical |
UNE-EN 50270:2016 | Identical |
DIN EN 50270 : 2015 COR 1 2016 | Identical |
VDE 0843-30 : 2015 COR 1 2016 | Identical |
UNE-EN 50270:2015 | Identical |
SN EN 50270:2015 | Identical |
BS EN 50270:2015 | Identical |
CEI EN 50270 : 2015 | Identical |
SN EN 50270 : 2015 COR 2016 | Identical |
13/30276476 DC : 0 | BS EN 45544-3 - WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR GENERAL GAS DETECTION |
BS EN 50543:2011 | Electronic portable and transportable apparatus designed to detect and measure carbon dioxide and/or carbon monoxide in indoor ambient air. Requirements and test methods |
BS EN 50379-2:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances Performance requirements for apparatus used in statutory inspections and assessment |
BS EN 50104:2010 | Electrical apparatus for the detection and measurement of oxygen. Performance requirements and test methods |
BS EN 45544-3:2015 | Workplace atmospheres. Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours Performance requirements for apparatus used for general gas detection |
UNE-EN 50194-2:2007 | Electrical apparatus for the detection of combustible gases in domestic premises - Part 2: Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises - Additional test methods and performance requirements |
BS EN 50291:2001 | Electrical apparatus for the detection of carbon monoxide in domestic premises. Test methods and performance requirements |
PREN 45544-2 : DRAFT 2013 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR EXPOSURE MANAGEMENT |
BS 7927:1998 | Heating appliances for domestic applications. Portable apparatus designed to detect and measure specific combustion flue gas products. Requirements |
08/30176065 DC : DRAFT JAN 2008 | BS EN 50194-1 - ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS |
CEI EN 50379-3 : 2012 | SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED IN NON-STATUTORY SERVICING OF GAS FIRED HEATING APPLIANCES |
BS ISO 16000-29:2014 | Indoor air Test methods for VOC detectors |
BS EN 45544-1:2015 | Workplace atmospheres. Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours General requirements and test methods |
BS EN 50194:2000 | Electrical apparatus for the detection of combustible gases in domestic premises. Test methods and performance requirements |
DIN EN 50402 : 2018 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF GAS DETECTION SYSTEMS |
CEI EN 50291 : 2002 | ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES TEST METHODS AND PERFORMANCE REQUIREMENTS |
CEI EN 50104 : 2011 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF OXYGEN - PERFORMANCE REQUIREMENTS AND TEST METHODS |
I.S. EN 50402:2017 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF FIXED GAS DETECTION SYSTEMS |
BS EN 50291-1 : 2010 | ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS |
BS EN 50545-1 : 2011 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF TOXIC AND COMBUSTIBLE GASES IN CAR PARKS AND TUNNELS - PART 1: GENERAL PERFORMANCE REQUIREMENTS AND TEST METHODS FOR THE DETECTION AND MEASUREMENT OF CARBON MONOXIDE AND NITROGEN OXIDES |
UNE-EN 50543:2011 | Electronic portable and transportable apparatus designed to detect and measure carbon dioxide and/or carbon monoxide in indoor ambient air - Requirements and test methods |
CEI EN 50379-1 : 2012 | SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
PREN 45544-3 : DRAFT 2013 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR GENERAL GAS DETECTION |
CEI EN 60079-29-4 : 2011 | EXPLOSIVE ATMOSPHERES - PART 29-4: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF OPEN PATH DETECTORS FOR FLAMMABLE GASES |
UNE-EN 50379-1:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 1: General requirements and test methods |
I.S. EN 61779-1:2003 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
VDE 0400-70 : 2018 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF GAS DETECTION SYSTEMS |
I.S. EN 50545-1:2011 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF TOXIC AND COMBUSTIBLE GASES IN CAR PARKS AND TUNNELS - PART 1: GENERAL PERFORMANCE REQUIREMENTS AND TEST METHODS FOR THE DETECTION AND MEASUREMENT OF CARBON MONOXIDE AND NITROGEN OXIDES |
BS EN 50291-2:2010 | Electrical apparatus for the detection of carbon monoxide in domestic premises Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft. Additional test methods and performance requirements |
EN 50379-3:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 3: Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances |
EN 50379-1:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 1: General requirements and test methods |
(INVALID RECORD) EN 50543:2011/AC:2011 | ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS |
EN 60079-29-4:2010 | Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases |
EN 50291:2001 | Electrical apparatus for the detection of carbon monoxide in domestic premises - Test methods and performance requirements |
EN 50241-2:1999 | Specification for open path apparatus for the detection of combustible or toxic gases and vapours - Part 2: Performance requirements for apparatus for the detection of combustible gases |
OVE/ONORM EN 60079-29-1 : 2008 | EXPLOSIVE ATMOSPHERES - PART 29-1: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF DETECTORS FOR FLAMMABLE GASES |
CEI EN 50543 : 2011 | ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS |
NF EN 50194 : 2000 CORR 1 2000 | ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - TEST METHODS AND PERFORMANCE REQUIREMENTS |
02/203341 DC : DRAFT FEB 2002 | PREN 50379-1 - SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
EN 60079-29-1:2016 | Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases |
BS EN 50402:2017 | Electrical apparatus for the detection and measurement of combustible or toxic gases or vapours or of oxygen. Requirements on the functional safety of gas detection systems |
CEI 216-8 : 2005 | FLUSH-TYPE DETECTORS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - TEST METHODS AND PERFORMANCE REQUIREMENTS |
UNE-EN 60079-29-4:2011 | Explosive atmospheres -- Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases |
UNE-EN 50104:2011 | Electrical apparatus for the detection and measurement of oxygen - Performance requirements and test methods |
PREN 50402 : DRAFT 2013 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF FIXED GAS DETECTION SYSTEMS |
CEI UNI EN 50194 : 2001 | ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - TEST METHODS AND PERFORMANCE REQUIREMENTS |
CEI 216-5/1 : 2002 | ELECTRICAL EQUIPMENT FOR THE DETECTION AND THE MEASUREMENT OF BURNING VAPOURS OR GASES OR TOXIC AND OF OXYGEN FOR CONTINUOUS OPERATION IN FIXED INSTALLATIONS IN NON-HAZARDOUS AREAS - PART 1:GENERAL REQUIREMENTS AND TEST METHODS FOR CONTROL BOARDS AND CONTROL AND SIGNALLING BOARDS |
EN 50402:2017 | Electrical apparatus for the detection and measurement of combustible or toxic gases or vapours or of oxygen - Requirements on the functional safety of gas detection systems |
I.S. EN 50194-2:2006 | ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 2: ELECTRICAL APPARATUS FOR CONTINUOUS OPERATION IN A FIXED INSTALLATION IN RECREATIONAL VEHICLES AND SIMILAR PREMISES - ADDITIONAL TEST METHODS AND PERFORMANCE REQUIREMENTS |
UNE-EN 60079-29-1:2017 | Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases |
UNE-EN 50291-1:2011 | Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 1: Test methods and performance requirements |
ISA 92.00.01 : 2010(R2015) | PERFORMANCE REQUIREMENTS FOR TOXIC GAS DETECTORS |
I.S. EN 45544-2:2015 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR EXPOSURE MEASUREMENT |
I.S. EN 50104:2010 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF OXYGEN - PERFORMANCE REQUIREMENTS AND TEST METHODS |
BS EN 50194-2 : 2006 | ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 2: ELECTRICAL APPARATUS FOR CONTINUOUS OPERATION IN A FIXED INSTALLATION IN RECREATIONAL VEHICLES AND SIMILAR PREMISES - ADDITIONAL TEST METHODS AND PERFORMANCE REQUIREMENTS |
NF EN 50545-1 : 2012 AMD 1 2016 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF TOXIC AND COMBUSTIBLE GASES IN CAR PARKS AND TUNNELS - PART 1: GENERAL PERFORMANCE REQUIREMENTS AND TEST METHODS FOR THE DETECTION AND MEASUREMENT OF CARBON MONOXIDE AND NITROGEN OXIDES |
CEI UNI EN 50194-1 : 2012 | ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS |
NF EN 50291-1 : 2010 AMD 1 2012 | ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS |
EN 50291-1:2018 | Gas detectors - Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 1: Test methods and performance requirements |
FM 6320 : 2018 | COMBUSTIBLE GAS DETECTORS |
EN 45544-1:2015 | Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 1: General requirements and test methods |
VDI 4206 Blatt 1:2010-08 | Performance criteria and test procedures for measuring devices for monitoring emissions at firing installations - Measuring devices for the determination of gaseous emissions and flue gas parameters |
VDE 0400-40-1 : 2000 AMD 1 2004 | SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
VDI 4206 Blatt 4:2013-08 | Performance criteria and test procedures for measuring devices for monitoring emissions at small firing installations - Measuring devices for the determination of moisture of lumpy wood |
DIN EN 61779-1 : 2001 AMD 11 2004 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
VDE 0400-40-2 : 2000 | SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES |
13/30275012 DC : 0 | BS EN 45544-1 - WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
DIN EN 50241-1 : 2000 AMD 1 2004 | SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
UNI CEI EN 50194-1 : 2010 | ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS |
EN 303 446-2 : 1.1.0 DRAFT | ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR COMBINED AND/OR INTEGRATED RADIO AND NON-RADIO EQUIPMENT; PART 2: SPECIFIC CONDITIONS FOR EQUIPMENT INTENDED TO BE USED IN INDUSTRIAL LOCATIONS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.1(B) OF DIRECTIVE 2014/53/EU |
PREN 50543 : DRAFT 2009 | ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS |
06/30150303 DC : DRAFT MAY 2006 | EN 50291-1 - ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS |
DIN EN 50241-2 : 2000 | SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES |
13/30260728 DC : 0 | BS EN 50402 - ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE OR TOXIC GASES OR VAPOURS OR OF OXYGEN - REQUIREMENTS ON THE FUNCTIONAL SAFETY OF FIXED GAS DETECTION SYSTEMS |
09/30214233 DC : 0 | BS EN 50543 - ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS |
13/30276473 DC : 0 | BS EN 45544-2 - WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR EXPOSURE MANAGEMENT |
BS EN 50241-1:1999 | Specification for open path apparatus for the detection of combustible or toxic gases and vapours General requirements and test methods |
CEI EN 50379-2 : 2012 | SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED IN STATUTORY INSPECTIONS AND ASSESSMENT |
02/203342 DC : DRAFT FEB 2002 | PREN 50379-2 - SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED IN STATUTORY INSPECTIONS AND ASSESSMENT |
I.S. EN 50291-1:2010 | GAS DETECTORS - ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS |
BS EN 60079-29-4:2010 | Explosive atmospheres Gas detectors. Performance requirements of open path detectors for flammable gases |
BS EN 60079-29-1:2007 | Explosive atmospheres Gas detectors. Performance requirements of detectors for flammable gases |
I.S. EN 50543:2011 | ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS |
I.S. EN 50241-2:1999 | SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES |
UNE-EN 50291-2:2011 | Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 2: Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft - Additional test methods and performance requirements |
EN 45544-3:2015 | Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 3: Performance requirements for apparatus used for general gas detection |
EN 50241-1 : 99 AMD 1 2004 | SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
EN 45544-2:2015 | Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 2: Performance requirements for apparatus used for exposure measurement |
NF EN 50543 : 2011 | ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS |
BS EN 50379-3:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances |
DIN ISO 16000-29:2015-02 | INDOOR AIR - PART 29: TEST METHODS FOR VOC DETECTORS (ISO 16000-29:2014) |
BS EN 45544-2:2015 | Workplace atmospheres. Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours Performance requirements for apparatus used for exposure measurement |
08/30184950 DC : DRAFT JULY 2008 | BS EN 50291-1 - ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS |
UNE-EN 50545-1:2012 | Electrical apparatus for the detection and measurement of toxic and combustible gases in car parks and tunnels - Part 1: General performance requirements and test methods for the detection and measurement of carbon monoxide and nitrogen oxides |
BS EN 50241-2:1999 | Specification for open path apparatus for the detection of combustible or toxic gases and vapours Performance requirements for apparatus for the detection of combustible gases |
CEI 216-5/3 : 2002 | ELECTRICAL EQUIPMENT FOR THE DETECTION AND THE MEASUREMENT OF FLAMMABLE VAPOURS OR GASES OR TOXIC AND OF OXYGEN FOR CONTINUOUS OPERATION IN FIXED INSTALLATIONS IN NON-HAZARDOUS AREAS - PART 3:GENERAL REQUIREMENTS AND TEST METHODS FOR DETECTORS OF GASES AND FLAMMABLE VAPOURS WITH PROPORTIONAL OUTPUTS |
BS EN 50379-1:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances General requirements and test methods |
I.S. EN 45544-1:2015 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
UNE-EN 50379-2:2013 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 2: Performance requirements for apparatus used in statutory inspections and assessment |
CEI EN 50291-2 : 2011 | ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES - PART 2: ELECTRICAL APPARATUS FOR CONTINUOUS OPERATION IN A FIXED INSTALLATION IN RECREATIONAL VEHICLES AND SIMILAR PREMISES INCLUDING RECREATIONAL CRAFT - ADDITIONAL TEST METHODS AND PERFORMANCE REQUIREMENTS |
I.S. EN 50379-2:2012 | SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED IN STATUTORY INSPECTIONS AND ASSESSMENT |
I.S. EN 50194-1:2009 | ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 1: TEST METHODS AND PERFORMANCE REQUIREMENTS |
I.S. EN 50379-3:2012 | SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED IN NON-STATUTORY SERVICING OF GAS FIRED HEATING APPLIANCES |
I.S. EN 45544-3:2015 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR GENERAL GAS DETECTION |
I.S. EN 50379-1:2012 | SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
UNE-EN 50379-3:2013 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 3: Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances |
BS EN 50194-1:2009 | Electrical apparatus for the detection of combustible gases in domestic premises Test methods and performance requirements |
02/203343 DC : DRAFT FEB 2002 | PREN 50379-3 - SPECIFICATION FOR PORTABLE ELECTRICAL APPARATUS DESIGNED TO MEASURE COMBUSTION FLUE GAS PARAMETERS OF HEATING APPLIANCES - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED IN NON-STATUTORY SERVICING OF GAS FIRED HEATING APPLIANCES |
BS EN 61779-1:2000 | Electrical apparatus for the detection and measurement of flammable gases General requirements and test methods |
I.S. EN 60079-29-1:2016 | EXPLOSIVE ATMOSPHERES - PART 29-1: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF DETECTORS FOR FLAMMABLE GASES |
CEI 216-5/2 : 2002 | ELECTRICAL EQUIPMENT FOR THE DETECTION AND THE MEASUREMENT OF BURNING VAPOURS OR GASES OR TOXIC AND OF OXYGEN FOR CONTINUOUS OPERATION IN FIXED INSTALLATIONS IN NON-HAZARDOUS AREAS PART 2:GENERAL REQUIREMENTS AND TEST METHODS FOR DETECTORS OF GASES AND FLAMMABLE VAPOURS WITH ONE OR MORE FIXED ALARM LEVELS |
NF EN 60079-29-4 : 2010 | EXPLOSIVE ATMOSPHERES - PART 29-4: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF OPEN PATH DETECTORS FOR FLAMMABLE GASES |
I.S. EN 50291-2:2010 | ELECTRICAL APPARATUS FOR THE DETECTION OF CARBON MONOXIDE IN DOMESTIC PREMISES - PART 2: ELECTRICAL APPARATUS FOR CONTINUOUS OPERATION IN A FIXED INSTALLATION IN RECREATIONAL VEHICLES AND SIMILAR PREMISES INCLUDING RECREATIONAL CRAFT - ADDITIONAL TEST METHODS AND PERFORMANCE REQUIREMENTS |
ISO 16000-29:2014 | Indoor air — Part 29: Test methods for VOC detectors |
I.S. EN 60079-29-4:2010 | EXPLOSIVE ATMOSPHERES - PART 29-4: GAS DETECTORS - PERFORMANCE REQUIREMENTS OF OPEN PATH DETECTORS FOR FLAMMABLE GASES |
I.S. EN 50241-1:1999 | SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - GENERAL REQUIREMENTS AND TEST METHODS |
EN 50379-2:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 2: Performance requirements for apparatus used in statutory inspections and assessment |
EN 61779-1 : 2000 AMD 11 2004 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
EN 50104:2010 | Electrical apparatus for the detection and measurement of oxygen - Performance requirements and test methods |
EN 45544-1:2015 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
EN 45544-2 : 2015 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR EXPOSURE MEASUREMENT |
EN 50194:2000 | Electrical apparatus for the detection of combustible gases in domestic premises - Part 1: Test methods and performance requirements |
EN 50194-2 : 2006 AMD 1 2016 | ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 2: ELECTRICAL APPARATUS FOR CONTINUOUS OPERATION IN A FIXED INSTALLATION IN RECREATIONAL VEHICLES AND SIMILAR PREMISES - ADDITIONAL TEST METHODS AND PERFORMANCE REQUIREMENTS |
EN 45544-3 : 2015 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR GENERAL GAS DETECTION |
EN 50291-2:2010 | Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 2: Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft - Additional test methods and performance requirements |
EN 50194-1:2009 | Electrical apparatus for the detection of combustible gases in domestic premises - Part 1: Test methods and performance requirements |
EN 50545-1:2011/A1:2016 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF TOXIC AND COMBUSTIBLE GASES IN CAR PARKS AND TUNNELS - PART 1: GENERAL PERFORMANCE REQUIREMENTS AND TEST METHODS FOR THE DETECTION AND MEASUREMENT OF CARBON MONOXIDE AND NITROGEN OXIDES |
EN 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements |
EN 50104:2010 | Electrical apparatus for the detection and measurement of oxygen - Performance requirements and test methods |
EN 61326-3-2:2008 | Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment |
EN 61000-6-1:2007 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments |
IEC 61326-3-2:2017 | Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment |
EN 50379-3:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 3: Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances |
EN 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements |
EN 60079-29-4:2010 | Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases |
EN 45544-3 : 2015 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 3: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR GENERAL GAS DETECTION |
EN 61000-6-3:2007/A1:2011/AC:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010) |
EN 45544-1:2015 | Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 1: General requirements and test methods |
EN 60079-29-1:2016 | Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 50194-2 : 2006 AMD 1 2016 | ELECTRICAL APPARATUS FOR THE DETECTION OF COMBUSTIBLE GASES IN DOMESTIC PREMISES - PART 2: ELECTRICAL APPARATUS FOR CONTINUOUS OPERATION IN A FIXED INSTALLATION IN RECREATIONAL VEHICLES AND SIMILAR PREMISES - ADDITIONAL TEST METHODS AND PERFORMANCE REQUIREMENTS |
EN 50379-2:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 2: Performance requirements for apparatus used in statutory inspections and assessment |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
IEC 60079-29-4:2009 | Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases |
EN 50291-2:2010 | Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 2: Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft - Additional test methods and performance requirements |
EN 50402:2017 | Electrical apparatus for the detection and measurement of combustible or toxic gases or vapours or of oxygen - Requirements on the functional safety of gas detection systems |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 45544-2:2015 | Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 2: Performance requirements for apparatus used for exposure measurement |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 60079-11:2012 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
EN 61326-1:2013 | Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
EN 50545-1:2011/A1:2016 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF TOXIC AND COMBUSTIBLE GASES IN CAR PARKS AND TUNNELS - PART 1: GENERAL PERFORMANCE REQUIREMENTS AND TEST METHODS FOR THE DETECTION AND MEASUREMENT OF CARBON MONOXIDE AND NITROGEN OXIDES |
EN 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems |
(INVALID RECORD) EN 50543:2011/AC:2011 | ELECTRONIC PORTABLE AND TRANSPORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE AND/OR CARBON MONOXIDE IN INDOOR AMBIENT AIR - REQUIREMENTS AND TEST METHODS |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
EN 61000-6-4:2007/A1:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 50271:2010 | Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen - Requirements and tests for apparatus using software and/or digital technologies |
EN 45544-1:2015 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
IEC 61000-6-4:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
EN 50379-1:2012 | Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances - Part 1: General requirements and test methods |
EN 50194-1:2009 | Electrical apparatus for the detection of combustible gases in domestic premises - Part 1: Test methods and performance requirements |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 45544-3:2015 | Workplace atmospheres - Electrical apparatus used for the direct detection and direct concentration measurement of toxic gases and vapours - Part 3: Performance requirements for apparatus used for general gas detection |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
IEC 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
IEC 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508) |
EN 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
EN 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations |
EN 45544-2 : 2015 | WORKPLACE ATMOSPHERES - ELECTRICAL APPARATUS USED FOR THE DIRECT DETECTION AND DIRECT CONCENTRATION MEASUREMENT OF TOXIC GASES AND VAPOURS - PART 2: PERFORMANCE REQUIREMENTS FOR APPARATUS USED FOR EXPOSURE MEASUREMENT |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.