EN 50377-7-1:2004
Current
Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 7-1: Type LC-PC duplex terminated on IEC 60793-2 category A1a and A1b multimode fibre
05-28-2004
1 Scope
1.1 Product definition
1.2 Intermateability
1.3 Operating environment
1.4 Reliability
1.5 Quality assurance
2 Normative references
3 Description
3.1 Plug
3.2 Adaptor
3.3 Materials
3.4 Dimensions
3.5 Colour and marking
4 Variants
4.1 Terminated plug
4.2 Adaptor
4.3 Identification of variants
5 Dimensional requirements
5.1 Outline dimensions
5.1.1 Plug variants
5.1.2 Adaptor variants
5.2 Mating face and other limit dimensions
5.2.1 Plug
5.2.2 Ferrule endface geometry after termination
5.2.3 Adaptor
5.2.4 Pin gauge for adaptor
6 Tests
6.1 Sample size
6.2 Test and measurement methods
6.3 Test sequence
6.4 Pass/Fail criteria
7 Test report
8 Testing requirements
8.1 Dimensional and marking requirements
8.2 Optical Performance requirements
8.3 Mechanical Performance requirements
8.4 Environmental Performance requirements
Annex A (informative) Attenuation reference plug details
Annex B (informative) Sample size and product sourcing
requirements
Bibliography
1.1Product definitionThis European Standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements which a terminated and assembled multimode resilient alignment sleeve LC-PC duplex connector set (plug / adaptor / plug) must meet in order for it to be categorised as an European Standard product.Since different variants and grades of performance are permitted, product marking details are given in 3.5.1.2IntermateabilityAlthough all products conforming to the requirements of this European Standard will intermate, the resulting level of random attenuation performance will only be ensured in accordance with Table 1. The intention is that this will be true irrespective of the manufacturing source(s) of the product.A simplex plug can be connected in a duplex adaptor without degrading the level of performance.1.3Operating environmentThe tests selected combined with the severities and duration's are representative of an indoor environment typically, but not limited to, that found in generic cabling on commercial premises as defined as in ISO/IEC 11801 and EN 50173 and specified as IEC category C.1.4ReliabilityWhilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with this European Standard does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme.1.5Quality assuranceCompliance with this European Standard does not guarantee the manufacturing consistency of the product. This should be maintained using a recognised quality assurance programme.
| Committee |
CLC/TC 86BXA
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Current
|
| Standards | Relationship |
| NEN EN 50377-7-1 : 2004 | Identical |
| NBN EN 50377 7-1 : 2005 | Identical |
| PN EN 50377-7-1 : 2006 | Identical |
| I.S. EN 50377-7-1:2004 | Identical |
| NF EN 50377-7-1 : 2004 | Identical |
| CEI EN 50377-7-1 : 2005 | Identical |
| DIN EN 50377-7-1:2004-10 | Identical |
| BS EN 50377-7-1:2004 | Identical |
| UNE-EN 50377-7-1:2004 | Identical |