EN 50397-2:2009
Withdrawn
Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV AC and not exceeding 36 kV AC - Part 2: Accessories for covered conductors - Tests and acceptance criteria
10-30-2009
05-01-2012
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Quality assurance
6 Classification of tests - Type tests, sample tests,
routine tests
7 Tests
Annex A (normative) - Type tests, sample tests and routine
tests
Annex B (informative) - Example of sampling with inspection
by attributes
Annex C (informative) - Example of sampling with inspection
by variable
Annex D (normative) - Special national conditions
Bibliography
Covered overhead line conductors are equipped with a plastic covering (XLPE-based) as protection against accidental contact with grounded parts respectively against accidental contact with other, at least covered live parts (e.g. other covered overhead line conductors) - This plastic cover is not a touch-proof, full protecting insulation - The covered overhead line conductors are designed for the use in high-voltage overhead lines with rated voltages up to 30 kV AC - The application of covered overhead line conductors is exclusively allowed on suitable insulators, which are designed for the rated voltage of the overhead line - As protection against negative influences by water penetration, the conductor may be equipped with measures to maintain longitudinal water tightness
| Committee |
CLC/TC 20
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Withdrawn
|
| Standards | Relationship |
| VDE 0276-397-2 : 2010 | Identical |
| NEN EN 50397-2 : 2009 | Identical |
| DIN EN 50397-2 : 2010 | Identical |
| NF EN 50397-2 : 2010 | Identical |
| BS EN 50397-2:2009 | Identical |
| PN EN 50397-2 : 2009 | Identical |
| NBN EN 50397-2 : 2010 | Identical |
| I.S. EN 50397-2:2009 | Identical |
| CEI EN 50397-2 : 2011 | Identical |
| BS EN 61915-1:2008 | Identical |
| UNE-EN 50397-2:2010 | Identical |
| EN 50397-3:2010 | Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. - Part 3: Guide to use |
| BS EN 50397-3:2010 | Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. Guide to use |
| 08/30182118 DC : DRAFT OCT 2008 | BS EN 50397-3 - COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE |
| CEI EN 50397-3 : 2011 | COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE |
| NF EN 50397-3 : 2010 | COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE |
| I.S. EN 50397-3:2010 | COVERED CONDUCTORS FOR OVERHEAD LINES AND THE RELATED ACCESSORIES FOR RATED VOLTAGES ABOVE 1 KV A.C. AND NOT EXCEEDING 36 KV A.C. - PART 3: GUIDE TO USE |
| IEC 60826:2017 | Design criteria of overhead transmission lines |
| EN 50483-5:2009 | Test requirements for low voltage aerial bundled cable accessories - Part 5: Electrical ageing test |
| IEC 61467:2008 | Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests |
| EN 50397-1:2006 | Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. - Part 1: Covered conductors |
| EN ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods (ISO 1461:2009) |
| ISO 1461:2009 | Hot dip galvanized coatings on fabricated iron and steel articles — Specifications and test methods |
| ISO 2859-2:1985 | Sampling procedures for inspection by attributes — Part 2: Sampling plans indexed by limiting quality (LQ) for isolated lot inspection |
| EN 50483-6:2009 | Test requirements for low voltage aerial bundled cable accessories - Part 6: Environmental testing |
| HD 474 : 200S1 | DIMENSIONS OF BALL AND SOCKET COUPLINGS OF STRING INSULATOR UNITS |
| IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
| ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
| IEC 60120:1984 | Dimensions of ball and socket couplings of string insulator units |
| EN ISO 9000:2015 | Quality management systems - Fundamentals and vocabulary (ISO 9000:2015) |
| EN 61284:1997 | Overhead lines - Requirements and tests for fittings |
| EN 61467:2008 | Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests |