• Shopping Cart
    There are no items in your cart
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

EN 55017:2011

Current

Current

Methods of measurement of the suppression characteristics of passive EMC filtering devices

Published date

09-30-2011

Sorry this product is not available in your region.
Summarise this standard

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Classification of EMC filtering devices
5 Insertion loss measurement
6 Impedance measurement
7 S-parameter measurement
8 Presentation of results
Annex A (normative) - Uncertainty estimation for the
        measurement of the suppression characteristics
        of EMC filtering devices
Annex B (informative) - Examples of test boxes for
        insertion loss measurement
Annex C (informative) - Insertion loss test methods
        with non-50 ohm systems
Annex D (informative) - Realization of the buffer-network
        for insertion loss measurement
Annex E (informative) - Insertion loss measurement -
        General discussion
Annex F (informative) - Set-up for impedance measurement
Annex G (informative) - S-parameter measurement of
        common-mode choke coils
Annex H (informative) - Measurement set-up for
        S-parameters of a DUT without wire leads
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

CISPR 17:2011 specifies methods to measure the radio interference suppression characteristics of passive EMC filtering devices used in power and signal lines, and in other circuits. The defined methods may also be applied to combinations of over-voltage protection devices and EMC filtering devices. The measurement method covers the frequency range from 9 kHz to several GHz depending on the device and test circuit. The standard describes procedures for laboratory tests (type tests) as well as factory tests. The suppression characteristics of EMC filters and components used for the suppression of EM disturbances, are a function of numerous variables such as impedance of the circuits to which they connect, operating voltage and current, and ambient temperature. This standard specifies uniform test methods that will enable comparison of filtering and suppression characteristics determined by test laboratories or specified by manufacturers. Measurement procedures are provided for unbiased and bias conditions. Measurements under bias conditions are performed to determine potential non-linear behaviour of the EMC filtering devices such as saturation effects in inductors with magnetic cores. This testing serves to show the usability in a specific application (such as frequency converters that produce high amplitudes of common mode pulse current and thus may drive inductors into saturation). Measurement under bias conditions may be omitted if the non-linear behaviour can be determined by other methods (e.g. separate saturation measurement of the inductors used). The first edition of CISPR 17 (1981) prescribed the measurement methods of insertion loss mainly for power-line filters. Today, however, many types of sophisticated EMC filters and suppression components can be found in various electronic devices. Those filters need to be characterized using standardized measurement methods. New methods for measurement of impedance and S-parameters for such EMI devices are included in this second edition.

Committee
CLC/TC 210
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

Standards Relationship
CEI EN 55017 : 2012 Identical
CISPR 17:2011 Identical
PN EN 55017 : 2011 Identical
DIN EN 55017:2012-04 Identical
NEN EN 55017 : 2011 Identical
BS EN 55017:2011 Identical
NF EN 55017 : 2012 Identical
I.S. EN 55017:2011 Identical
NBN EN 55017 : 2011 Identical
VDE 0565-17:2012-04 Identical
UNE-EN 55017:2012 Identical

Sorry this product is not available in your region.