EN 60229:2008

Current

Current

Electric cables - Tests on extruded oversheaths with a special protective function

Published date

06-04-2008

Sorry this product is not available in your region.
Summarise this standard

FOREWORD
1 Scope
2 Normative references
3 Routine tests
  3.1 D.C. voltage test
  3.2 Spark test
4 Type tests
  4.1 Abrasion test
      4.1.1 Purpose
      4.1.2 Test procedure
      4.1.3 Inspection
      4.1.4 Performance requirement
  4.2 Corrosion spread (aluminium metallic screen only)
      4.2.1 General
      4.2.2 Test procedure
      4.2.3 Inspection
      4.2.4 Performance requirement
5 Electrical test after installation
Annex A (normative) Application of the abrasion test
Annex B (informative) Guidance on tests after installation
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications

Provides a range of tests which may be required for electric cables which have an extruded oversheath and where that oversheath performs a special protective function. The standard covers cables for use in insulated systems and in uninsulated systems. The tests are categorized for use as routine tests, type tests and tests after installation. These tests comprise of electrical routine tests on cable oversheath used in insulated or uninsulated systems, abrasion and corrosion spread type tests, electrical test on cable oversheath after installation. Routine tests and tests after installation, as specified in the relevant cable standards, are applicable for all situations. Type tests depend upon the nature of the system and the construction of the cable and do not have to be carried out for normal conditions of use. The significant technical changes with respect to the previous edition are as follows: - The text has been modified in order to consider the function of the oversheath, irrespective of the way the metallic sheath or screen of the cable is earthed because, in some cases, the oversheath is designed to act not only as a protection against corrosion, but also to reduce the risk of degradation of the cable insulation system. This requirement may be independent of the nature of the insulation and independent of the rated voltage of the cable. - More precise wording has been introduced regarding the application of some tests (if the sheaths or foils are bonded to the oversheath or not). - The test requirements have been revised in order to be in line with the standards published after the second edition. - The pressure test at high temperature has been deleted as the requirement is specified in the relevant cable standards. - A 'Guidance on tests after installation' (Annex B) has been included.

Committee
CLC/TC 20
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

Standards Relationship
NF EN 60229 : 2008 Identical
IEC 60229:2007 Identical
NBN EN 60229 : 2008 Identical
NEN EN IEC 60229 : 2008 Identical
I.S. EN 60229:2008 Identical
PN EN 60229 : 2008 Identical
DIN EN 60229:2009-04 Identical
VDE 0473-229:2009-04 Identical
BS EN 60229:2008 Identical
CEI EN 60229 : 2010 Identical
UNE-EN 60229:2009 Identical
BS EN IEC 60191-1:2018 Identical

Sorry this product is not available in your region.