EN 61010-2-040:2015
Superseded
View Superseded by
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040 Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
09-11-2015
12-09-2021
FOREWORD
1 Scope and object
2 Normative references
3 Terms and definitions
4 Tests
5 Marking and documentation
6 Protection against electric shock
7 Protection against mechanical HAZARDS and
against HAZARDS related to mechanical functions
8 Mechanical resistance to shock and impact
9 Protection against the spread of fire
10 Equipment temperature limits and resistance to heat
11 Protection against HAZARDS from fluids
12 Protection against radiation, including laser sources,
and against sonic and ultrasonic pressure
13 Protection against liberated gases, substances, explosion
and implosion
14 Components
15 Protection by interlocks
16 HAZARDS resulting from application
17 RISK assessment
Annexes
Annex G (informative) - Leakage and rupture from fluids
under pressure
Annex L (informative) - Index of defined terms
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 61010-2-040:2015 specifies safety requirements for electrical equipment intended for sterilization, washing, and disinfection of medical materials in the medical, veterinary, pharmaceutical and laboratory fields, when used under the environmental conditions of 1.4. It has the status of a group safety publication, as specified in IEC Guide 104. This second edition cancels and replaces the first edition published in 2005. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:a) A new clause (4.3.2.101) has been added for non-electrical supplies and services.b) Additional requirements for marking and documentation (Clause 5) have been added.c) Additional requirements for protection against mechanical hazards (Clause 7) have been included.d) Additional requirements for protection against radiation, including laser sources, and against sonic and ultrasonic pressure (Clause 12) have been included.
| Committee |
CLC/TC 66X
|
| DevelopmentNote |
Supersedes EN 61010-2-041, EN 61010-2-042, EN 61010-2-043 & EN 61010-2-045. (08/2005)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| ONORM OVE EN 61010-2-040 : 2016 | Identical |
| VDE 0411-2-040 : 2016 | Identical |
| CEI EN 61010-2-040 : 2016 | Identical |
| I.S. EN 61010-2-040:2015 | Identical |
| IEC 61010-2-040:2015 | Identical |
| DIN EN 61010-2-040 : 2016 | Identical |
| NF EN 61010 2-040 : 2015 | Identical |
| BS EN 61010-2-040:2015 | Identical |
| PN EN 61010-2-040 : 2015 | Identical |
| NEN EN IEC 61010-2-040 : 2015 | Identical |
| NBN EN 61010 2-040 : 2015 | Identical |
| UNE-EN 61010-2-040:2006 | Identical |
| UNE-EN 61010-2-040:2015 | Identical |