EN 61076-3-100:2000
Current
Connectors for use in d.c., low-frequency analogue and digital high speed data applications - Part 3-100: Rectangular connectors with assessed quality - Detail specification for a range of shielded connectors with trapezoidal-shaped shells and non-removable ribbon contacts on a 1,27 mm double row
01-14-2000
1 General data
1.1 Recommended method of mounting
1.1.1 Minimum and maximum number of contacts
1.2 Rating and characteristics
1.3 Normative references
1.4 Marking
1.5 IEC type designation
1.6 Ordering information
2 Technical data
2.1 General
2.2 Survey of styles and variants
2.3 Information on application
3 Dimensional information
3.1 General
3.2 Isometric view and common features (with locking
devices)
3.3 Mating information
3.3.1 Contact arrangements
3.3.2 Mating face dimensions
3.3.3 Contact mating dimensions
3.4 Fixed connectors
3.4.1 Dimensions
3.4.2 Terminations
3.5 Free connectors
3.5.1 Dimensions
3.5.2 Termination
3.6 Accessories
3.7 Mounting information
3.7.1 Hole pattern on printed boards
3.7.2 Panel cutout dimensions
4 Characteristics
4.1 Climatic category
4.2 Electrical
4.2.1 Creepage and clearance distance
4.2.2 Voltage proof
4.2.3 Current-carrying capacity
4.2.4 Initial contact resistance
4.2.5 Initial insulation resistance
4.3 Mechanical
4.3.1 Mechanical operation
4.3.2 Insertion and withdrawal forces
5 Test schedule
5.1 General
5.2 Test schedules
5.2.1 Basic (minimum) test schedule
5.2.2 Full test schedule
6 Quality assessment procedures
6.1 Qualification approval testing
6.1.1 Method 1
6.1.2 Method 2
6.2 Quality conformance inspection
6.2.1 Lot-by-lot tests
6.2.2 Periodic tests
6.3 Delayed delivery, re-inspection
Annex ZA (normative) Normative references to international
publications with their corresponding
European standards
IEC 61076-3-100:1999 applies to a range of shielded two-part connectors with trapezoidal-shaped shells and non-removable ribbon contacts on 1,27 mm double rows. The fixed connectors are provided with a post either for dip solder (type A, B, C, D) or non-accessible insulation displacement terminations (type E). The free connectors are provided with non-accessible insulation displacement terminations.
| Committee |
CLC/SR 48B
|
| DevelopmentNote |
To be read in conjunction with EN 61076-1 and EN 61076-3 (05/2001)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Current
|
| Standards | Relationship |
| IEC 61076-3-001:2008 | Identical |
| IEC 61076-3-100:1999 | Identical |
| NF EN 61076 3 100 : 2000 | Identical |
| NBN EN 61076 3-100 : 2000 | Identical |
| NEN EN IEC 61076-3-100 : 2000 | Identical |
| I.S. EN 61076-3-100:2000 | Identical |
| PN EN 61076-3-100 : 2002 | Identical |
| BS EN 61076-3-100:2000 | Identical |
| CEI EN 61076-3-100 : 2000 | Identical |
| DIN EN 61076-3-100:2000-10 | Identical |
| BS EN 60598-2-8:1997+A2:2008 | Identical |
| UNE-EN 61076-3-100:2000 | Identical |