EN 61158-4-11:2014
Current
Industrial communication networks - Fieldbus specifications - Part 4-11: Data-link layer protocol specification - Type 11 elements
10-31-2014
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 Overview of the DL-protocol
5 General structure and encoding of PhIDU and
DLPDU and related elements of procedure
6 DLPDU-specific structure, encoding and elements
of procedure
7 DLE elements of procedure
Bibliography
Annex ZA (normative) - Normative references
to international publications with their
corresponding European publications
IEC 61158-4-11:2014 specifies procedures for: the timely transfer of data and control information from one data-link user entity to a peer user entity, and among the data-link entities forming the distributed data-link service provider; procedures for giving communications opportunities to all participating DL entities, sequentially and in a cyclic manner for deterministic and synchronized transfer at cyclic intervals up to one millisecond; procedures for giving communication opportunities available for time-critical data transmission together with non-time-critical data transmission without prejudice to the time-critical data transmission; procedures for giving cyclic and acyclic communication opportunities for time-critical data transmission with prioritized access; procedures for giving communication opportunities based on standard ISO/IEC 8802-3 medium access control, with provisions for nodes to be added or removed during normal operation and the structure of the fieldbus DLPDUs used for the transfer of data and control information by the protocol of this standard, and their representation as physical interface data units. This third edition cancels and replaces the second edition published in 2010 and constitutes a technical revision. The main changes are: Subclauses 4.6.1, 4.6.4 and 5.4.6, Clause 6 and 7.2 for the loop-architecture are modified to cover the additional specifications for the higher data rate in the loop-architecture.
| Committee |
CLC/TC 65X
|
| DevelopmentNote |
Together with EN 61158-4-16, EN 61158-4-17, EN 61158-4-18, EN 61158-4-19, EN 61158-4-7, EN 61158-4-8, EN 61158-4-4, EN 61158-4-12, EN 61158-4-13, EN 61158-4-14, EN 61158-4-2, EN 61158-4-3 and EN 61158-4-1 supersedes EN 61158-4. (05/2008)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| IEC 61158-4-11:2014 | Identical |
| NF EN 61158-4-11 : 2015 | Identical |
| NBN EN 61158-4-11 : 2014 | Identical |
| NEN EN IEC 61158-4-11 : 2014 | Identical |
| I.S. EN 61158-4-11:2014 | Identical |
| PN EN 61158-4-11 : 2015 | Identical |
| BS EN 61158-4-11:2014 | Identical |
| CEI EN 61158-4-11 : 2016 | Identical |
| DIN EN 61158-4-11:2015-09 | Identical |
| UNE-EN 61158-4-11:2014 | Identical |