EN 61347-2-2:2012
Current
Lamp controlgear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps
03-02-2012
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for protective earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings of ballasts
14 Fault conditions
15 Transformer heating
16 Construction
17 Creepage distances and clearances
18 Screws, current-carrying parts and connections
19 Resistance to heat, fire and tracking
20 Resistance to corrosion
Annex A (normative) - Test to establish whether a
conductive part is a live part which may
cause an electric shock
Annex B (normative) - Particular requirements for
thermally protected lamp controlgear
Annex C (normative) - Particular requirements for
electronic lamp controlgear with means of
protection against overheating
Annex D (normative) - Requirements for carrying out
the heating tests of thermally protected
lamp controlgear
Annex E (normative) - Use of constant S other than
4500 in t[w] tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation
of the values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Particular additional requirements
for SELV d.c. or a.c. supplied electronic
step-down convertors for filament lamps
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
IEC 61347-2-2:2011 specifies particular safety requirements for electronic step-down convertors for use on d.c. supplies of up to 250 V or a.c. supplies of up to 1 000 V, at 50 Hz or 60 Hz and with rated output voltage 50 V r.m.s. at a frequency deviating from the supply frequency, or 120 V ripple free d.c. between conductors and between any conductor and earth, associated with tungsten-halogen lamps as specified in IEC 60357 and other filament lamps. This second edition of IEC 61347-2-2 replaces the first edition (2000), Amendment 1 (2005) and Amendment 2 (2006). The major modification for this second edition is the changeover from SELV equivalent to SELV. This publication is to be read in conjunction with IEC 61347-1:2007.
| Committee |
CLC/TC 34
|
| DevelopmentNote |
To be used in conjunction with EN 61347-1 (10/2003) Together with EN 61347-1 and parts 2-1, 2-3, 2-4, 2-5, 2-6, 2-7, 2-8 and 2-9 of EN 61347 supersedes EN 60920, EN 60922, EN 60924, EN 60926, EN 60928 and EN 61046. (07/2005)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| BS EN 61347-2-2:2012 | Identical |
| DIN EN 61347-2-2 : 2012 | Identical |
| CEI EN 61347-2-2 : 2012 | Identical |
| VDE 0712-32 : 2012 | Identical |
| NEN EN IEC 61347-2-2 : 2012 | Identical |
| PN EN 61347-2-2 : 2012 | Identical |
| IEC 61347-2-2:2011 | Identical |
| NBN EN 61347 2-2 : 2012 | Identical |
| NF EN 61347-2-2 : 2012 | Identical |
| I.S. EN 61347-2-2:2012 | Identical |
| DS EN 61347-2-2 : 2012 | Identical |
| UNE-EN 61347-2-2:2012 | Identical |