EN 61347-2-7:2012
Superseded
Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)
03-02-2012
11-26-2019
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for protective earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings of ballasts
14 Fault conditions
15 Starting conditions
16 Lamp current
17 Supply current
18 Maximum current in any lead (with cathode preheating)
19 Lamp operating current waveforms
20 Functional safety (EBLF)
21 Changeover operation
22 Recharging device
23 Protection against excessive discharge
24 Indicator
25 Remote control, rest mode, inhibition mode
26 Temperature cycling test and endurance test
27 Polarity reversal
28 Fault conditions
29 Construction
30 Creepage distances and clearances
31 Screws, current-carrying parts and connections
32 Resistance to heat, fire and tracking
33 Resistance to corrosion
34 Abnormal lamp conditions
35 Protection of associated components
Annex A (normative) - Test to establish whether a conductive
part is a live part, which may cause an electric shock
Annex B (normative) - Particular requirements for thermally
protected lamp controlgear
Annex C (normative) - Particular requirements for electronic
lamp control gear with means of protection against
overheating
Annex D (normative) - Requirements for carrying out the
heating test of thermally protected lamp control gear
Annex E (normative) - Use of constant S other than 4500 in
t[w] tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation of the
values of pulse voltages
Annex H (normative) - Tests
Annex I (normative) - Batteries for emergency lighting
luminaries
Annex J (informative) - Rest mode and inhibition mode
facilities
Annex K (normative) - Ballasts incorporating an automatic
testing function for emergency lighting operation
Annex L (informative) - Compatibility between normal mains
operation Electronic control gear and battery-powered
emergency operation control gear
Annex ZA (normative) - Normative references to
international publications with their corresponding
European publications
IEC 61347-2-7:2011 specifies particular safety requirements for battery supplied electronic controlgear for maintained and non-maintained emergency lighting purposes. It includes specific requirements for electronic controlgear and control units for self-contained luminaires for emergency lighting as specified by IEC 60598-2-22. This third edition cancels and replaces the second edition published in 2006. It constitutes a technical revision. Significant changes introduced into this third edition include: - modification of IEC 61347-2-7 to become a standard exclusively for d.c. battery supplied electronic controlgear for emergency lighting (self-contained) IEC 61347-2-3 Annex J is intended to cover centrally supplied emergency controlgear; - update of Clause 22 - Recharging devices; - modification of Clause 20 battery voltage characterisation to support EBLF measurement. This to simplify and increase reproducibility of testing; - rationalisation of requirements between IEC 61347-2-7 and IEC 60598-2-22 requirements of IEC 60598-2-22 being transferred to IEC 61347-2-7. This publication is to be read in conjunction with IEC 61347-1:2007.
| Committee |
CLC/TC 34
|
| DevelopmentNote |
To be used in conjunction with EN 61347-1 (10/2003) Together with EN 61347-1 and parts 2-1, 2-2, 2-3, 2-4, 2-5, 2-6, 2-8 and 2-9 of EN 61347 supersedes EN 60920, EN 60922, EN 60924, EN 60926, EN 60928 and EN 61046. (07/2005).
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Superseded
|
| Supersedes |
| Standards | Relationship |
| IEC 61347-2-7:2011+AMD1:2017 CSV | Identical |
| NBN EN 61347 2-7 : 2012 | Identical |
| NEN EN IEC 61347-2-7 : 2012 | Identical |
| I.S. EN 61347-2-7:2012 | Identical |
| PN EN 61347-2-7 : 2013 | Identical |
| VDE 0712-37 : 2012 | Identical |
| DIN EN 61347-2-7 : 2012 | Identical |
| NEN-EN-IEC 61347-2-7:2012/A1:2019 en | Identical |
| BS EN 61347-2-7:2012 | Identical |
| CEI EN 61347-2-7 : 2012 | Identical |
| NF EN 61347-2-7 : 2012 | Identical |
| UNE-EN 61347-2-7:2012 | Identical |