EN 61897:1998
Superseded
View Superseded by
Overhead lines - Requirements and tests for Stockbridge type aeolian vibration dampers
10-12-1998
04-24-2020
FOREWORD
1 Scope
2 Normative references
3 Definitions
4 General requirements
4.1 Design
4.2 Materials
4.3 Mass, dimensions and tolerances
4.4 Protection against corrosion
4.5 Manufacturing appearance and finish
4.6 Marking
4.7 Installation instructions
5 Quality assurance
6 Classification of tests
6.1 Type tests
6.1.1 General
6.1.2 Application
6.2 Sample tests
6.2.1 General
6.2.2 Application
6.2.3 Sampling, acceptance criteria
6.3 Routine tests
6.3.1 General
6.3.2 Application and acceptance criteria
6.4 Table of tests to be applied
7 Test methods
7.1 Visual examination
7.2 Verification of dimensions, materials and mass
7.3 Corrosion protection tests
7.3.1 Hot dip galvanized components (other than
messenger cable wires)
7.3.2 Ferrous components protected from corrosion
by methods other than hot dip galvanizing
7.3.3 Hot dip galvanized messenger cable wires
7.4 Non-destructive tests
7.5 Clamp slip test
7.6 Breakaway bolt test
7.7 Clamp bolt tightening test
7.8 Attachment of weights to messenger cable
7.9 Attachment of clamp to messenger cable test
7.10 Corona and radio interference voltage (RIV) tests
7.11 Damper performance tests
7.11.1 Performance test variants
7.11.2 Damper characteristic test
7.11.3 Damper effectiveness evaluation
7.11.3.1 Methods of evaluation
7.11.3.2 Laboratory test
7.11.3.3 Field test
7.11.3.4 Analytical method
7.12 Damper fatigue test
7.12.1 Test methods
7.12.2 Swept frequency method
7.12.3 Resonant frequency method
7.12.4 Acceptance criteria
Annex A (normative) Minimum technical details to be agreed
between purchaser and supplier
Annex B (informative) Examples of graphs relevant to damper
characteristic test
Annex C (normative) Wind power input curve
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Bibliography
Applies to Stockbridge type aeolian vibration dampers intended for single conductors or earth wires or conductor bundles where dampers are direclty attached to each subconductor.
| Committee |
CLC/TC 11
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| NBN EN 61897 : 1999 | Identical |
| NEN EN IEC 61897 : 1999 | Identical |
| I.S. EN 61897:1999 | Identical |
| PN EN 61897 : DEC 2002 | Identical |
| DIN EN 61897 : 1999 | Identical |
| VDE 0212-3 : 1999 | Identical |
| BS EN 61897:1999 | Identical |
| CEI EN 61897 : 1999 | Identical |
| NF EN 61897 : 2001 | Identical |
| IEC 61897:1998 | Identical |
| NF EN IEC 61897:2020 | Identical |
| UNE-EN 61897:2000 | Identical |