EN IEC 61340-4-4:2018
Current
Electrostatics - Part 4-4: Standard test methods for specific applications - Electrostatic classification of flexible intermediate bulk containers (FIBC)
04-06-2018
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Classification
5 Safe use of FIBC
6 Labelling
7 Requirements for FIBC
8 Atmosphere for conditioning, calibrating and testing
9 Test procedures
10 Test report
Annex A (informative) - Electrical breakdown voltage -
Typical voltage/time graphs
Annex B (normative) - Polypropylene pellets for ignition
testing
Annex C (informative) - Guidance on test methods for
manufacturing quality control
Annex D (normative) - Classification of hazardous areas
and zones
Annex E (informative) - Risks associated with cone discharges
Annex F (informative) - Explanation for resistance and
resistivity limits and thickness limits for insulating
layers of inner liners
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding
European publications
NEW!IEC 61340-4-4:2018 is available as IEC 61340-4-4:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 61340-4-4:2018 specifies requirements for flexible intermediate bulk containers (FIBC) between 0,25 m3 and 3 m3 in volume, intended for use in hazardous explosive atmospheres. The explosive atmosphere can be created by the contents in the FIBC or can exist outside the FIBC. The requirements include:
– classification and labelling of FIBC;
– classification of inner liners;
– specification of test methods for each type of FIBC, inner liner, labels and document pockets;
– design and performance requirements for FIBC, inner liners, labels and document pockets;
– safe use of FIBC (including those with inner liners) within different zones defined for explosion endangered environments, described for areas where combustible dusts are, or can be, present (IEC 60079-10-2), and for explosive gas atmospheres (IEC 60079-10-1);
– procedures for type qualification and certification of FIBC, including the safe use of inner liners. This third edition cancels and replaces the second edition, published in 2012, and Amendment 1:2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) in light of experimental evidence, the maximum resistance to ground limit for Type C FIBC, and corresponding resistance limits for inner liners used in Type C FIBC has been increased from 10 M ohms to 100 M ohms;
b) the classification of Type L1 inner liners has been revised and extended to include Type L1C inner liners made from multi-layer materials with a conductive internal layer;
c) a labelling requirement to include a reference to IEC TS 60079-32-1 for guidance on earthing has been added.
| Committee |
CLC/SR 101
|
| DevelopmentNote |
Supersedes & Redesignates EN 61340-4-4. (04/2018)
|
| DocumentType |
Standard
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Current
|
| Standards | Relationship |
| DS/EN IEC 61340-4-4:2018 | Identical |
| CEI EN IEC 61340-4-4:2018 | Identical |
| NEN-EN-IEC 61340-4-4:2018 | Identical |
| SS-EN IEC 61340-4-4:2018 | Identical |
| IEC 61340-4-4:2012+AMD1:2014 CSV | Identical |
| OVE EN IEC 61340-4-4: 2019 02 01 | Identical |
| BS EN IEC 61340-4-4:2018 | Identical |
| VDE 0300-4-4:2019-01 | Identical |
| DIN EN IEC 61340-4-4:2019-01 | Identical |
| I.S. EN IEC 61340-4-4:2018 | Equivalent |
| I.S. EN IEC 61340-4-4:2018 | Identical |
| UNE-EN IEC 61340-4-4:2018 | Identical |
| IEC 61340-4-4:2018 | Identical |