EN ISO 389-3:2016

Current

Current

Acoustics - Reference zero for the calibration of audiometric equipment - Part 3: Reference equivalent threshold vibratory force levels for pure tones and bone vibrators (ISO 389-3:2016)

Published date

02-17-2016

Sorry this product is not available in your region.
Summarise this standard

European foreword
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Reference equivalent threshold vibratory
  force levels (RETVFL)
5 Test conditions and requirements
Annex A (informative) - Note on the derivation of
        RETVFL values
Annex B (informative) - Guidance on the application
        of the reference zero to the calibration of bone-conduction
        audiometers
Annex C (informative) - Differences in reference equivalent
        threshold vibratory force levels between forehead and
        mastoid location of vibrator
Annex D (informative) - Bone-conduction threshold of hearing
        for frequencies below 250 Hz
Bibliography

ISO 389-1:2016 specifies the following data applicable to the calibration of bone vibrators for pure-tone bone-conduction audiometry:a) reference equivalent threshold vibratory force levels (RETVFL), corresponding to the threshold of hearing of young otologically normal persons by bone-conduction audiometry;b) essential characteristics of the bone vibrator and the method of coupling to the test subject, and to the mechanical coupler;c) essential characteristics of the masking noise and the baseline masking noise level applied to the ear not under test.Guidance on the practical application of this part of ISO 389 in the calibration of audiometers is given in Annex B.RETVFL is the vibratory force level transmitted to a mechanical coupler of specified characteristics by a vibrator when applied to the mechanical coupler under stated conditions of test and when energized at the voltage level corresponding to the normal threshold of hearing for location on the mastoid prominence.NOTE 1 Values for the differences in reference equivalent threshold vibratory force levels between location on the forehead and mastoid are included for information in Annex C.NOTE 2 Recommended procedures for carrying out bone-conduction audiometry are specified in ISO 8253‑1.

Committee
CEN/TC 211
DevelopmentNote
Supersedes EN 27566. (04/2005)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current