I.S. EN 16407-2:2014
Withdrawn
View Superseded by
NON-DESTRUCTIVE TESTING - RADIOGRAPHIC INSPECTION OF CORROSION AND DEPOSITS IN PIPES BY X- AND GAMMA RAYS - PART 2: DOUBLE WALL RADIOGRAPHIC INSPECTION
Hardcopy , PDF
English
01-25-2014
04-30-2019
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Classification of radiographic techniques
5 General
6 Recommended techniques for making radiographs
7 Radiograph/digital image sensitivity, quality
and evaluation
8 Measurement of differences in penetrated thickness
9 Digital image recording, storage, processing and
viewing
10 Test report
Annex A (normative) - Minimum image quality values
Annex B (informative) - Penetrated thickness measurements
from image grey levels
Annex C (normative) - Determination of basic spatial
resolution
Bibliography
Defines fundamental techniques of film and digital radiography with the object of enabling satisfactory and repeatable results to be obtained economically.
| DocumentType |
Standard
|
| Pages |
40
|
| PublisherName |
National Standards Authority of Ireland
|
| Status |
Withdrawn
|
| SupersededBy |
| Standards | Relationship |
| EN 16407-2:2014 | Identical |
| BS EN 16407-2:2014 | Equivalent |
| DIN EN 16407-2:2014-04 | Equivalent |
| UNE-EN 16407-2:2014 | Equivalent |
| ISO 17636-1:2013 | Non-destructive testing of welds — Radiographic testing — Part 1: X- and gamma-ray techniques with film |
| EN 12543-4:1999 | Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing - Part 4: Edge method |
| EN ISO 11699-2:2011 | Non-destructive testing - Industrial radiographic films - Part 2: Control of film processing by means of reference values (ISO 11699-2:1998) |
| EN 444:1994 | Non-destructive testing - General principles for radiographic examination of metallic materials by X- and gamma-rays |
| EN 12543-5:1999 | Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing - Part 5: Measurement of the effective focal spot size of mini and micro focus X-ray tubes |
| ASTM E 1000 : 2016 : REDLINE | Standard Guide for Radioscopy |
| EN 12543-2:2008 | Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing - Part 2: Pinhole camera radiographic method |
| EN ISO 19232-3:2013 | Non-destructive testing - Image quality of radiographs - Part 3: Image quality classes (ISO 19232-3:2013) |
| ISO 9712:2012 | Non-destructive testing — Qualification and certification of NDT personnel |
| EN ISO 19232-5:2013 | Non-destructive testing - Image quality of radiographs - Part 5: Determination of the image unsharpness value using duplex wire-type image quality indicators (ISO 19232-5:2013) |
| ISO 5576:1997 | Non-destructive testing — Industrial X-ray and gamma-ray radiology — Vocabulary |
| EN ISO 9712:2012 | Non-destructive testing - Qualification and certification of NDT personnel (ISO 9712:2012) |
| ASTM E 2736 : 2010 | Standard Guide for Digital Detector Array Radiology |
| EN ISO 11699-1:2011 | Non-destructive testing - Industrial radiographic film - Part 1: Classification of film systems for industrial radiography (ISO 11699-1:2008) |
| EN ISO 19232-1:2013 | Non-destructive testing - Image quality of radiographs - Part 1: Determination of the image quality value using wire-type image quality indicators (ISO 19232-1:2013) |
| EN ISO 19232-2:2013 | Non-destructive testing - Image quality of radiographs - Part 2: Determination of the image quality value using step/hole-type image quality indicators (ISO 19232-2:2013) |
| EN 25580:1992 | Non-destructive testing - Industrial radiographic illuminators - Minimum requirements (ISO 5580:1985) |
| ISO 19232-3:2013 | Non-destructive testing — Image quality of radiographs — Part 3: Image quality classes |
| ISO 5580:1985 | Non-destructive testing — Industrial radiographic illuminators — Minimum requirements |
| EN 12543-3:1999 | Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing - Part 3: Slit camera radiographic method |
| ISO 17636-2:2013 | Non-destructive testing of welds — Radiographic testing — Part 2: X- and gamma-ray techniques with digital detectors |
| ISO 11699-1:2008 | Non-destructive testing — Industrial radiographic film — Part 1: Classification of film systems for industrial radiography |
| EN ISO 19232-4:2013 | Non-destructive testing - Image quality of radiographs - Part 4: Experimental evaluation of image quality values and image quality tables (ISO 19232-4:2013) |
| EN ISO 17636-2:2013 | Non-destructive testing of welds - Radiographic testing - Part 2: X- and gamma-ray techniques with digital detectors (ISO 17636-2:2013) |
| ISO 19232-1:2013 | Non-destructive testing — Image quality of radiographs — Part 1: Determination of the image quality value using wire-type image quality indicators |
| ISO 19232-5:2013 | Non-destructive testing — Image quality of radiographs — Part 5: Determination of the image unsharpness value using duplex wire-type image quality indicators |
| EN 14784-1:2005 | Non-destructive testing - Industrial computed radiography with storage phosphor imaging plates - Part 1: Classification of systems |
| ISO 19232-2:2013 | Non-destructive testing — Image quality of radiographs — Part 2: Determination of the image quality value using step/hole-type image quality indicators |
| EN 14096-2:2003 | Non-destructive testing - Qualification of radiographic film digitisation systems - Part 2: Minimum requirements |
| EN ISO 17636-1:2013 | Non-destructive testing of welds - Radiographic testing - Part 1: X- and gamma-ray techniques with film (ISO 17636-1:2013) |
| EN 12543-1:1999 | Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing - Part 1: Scanning method |
| ISO 19232-4:2013 | Non-destructive testing — Image quality of radiographs — Part 4: Experimental evaluation of image quality values and image quality tables |
| ISO 11699-2:1998 | Non-destructive testing — Industrial radiographic films — Part 2: Control of film processing by means of reference values |