I.S. EN 60695-6-2:2011
Withdrawn
FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS (IEC 60695-6-2:2011)
Hardcopy , PDF
English
01-01-2011
07-10-2021
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Types of test method
5 Types of test specimen
6 Published static test methods
7 Published dynamic test methods
8 Overview of methods and relevance of data
Annex A (informative) - Repeatability and reproducibility
data - NBS smoke chamber - Interlaboratory tests
from the French standard NF C20-902-1 and NF C20-902-2
Annex B (informative) - Repeatability and reproducibility
data - ISO 5659-2
Annex C (informative) - Repeatability and reproducibility
data - 'Three metre cube' smoke chamber - French
interlaboratory tests according to IEC 61034-2
Annex D (informative) - Repeatability and reproducibility
data - NFPA 262
Annex E (informative) - Precision data of smoke measurement
in ISO 5660-2
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Bibliography
Defines a summary of the test methods that are used in the assessment of smoke obscuration.
| DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
| DocumentType |
Standard
|
| Pages |
40
|
| PublisherName |
National Standards Authority of Ireland
|
| Status |
Withdrawn
|
| Standards | Relationship |
| EN 60695-6-2:2011 | Identical |
| IEC 60695-6-2:2011 | Identical |
| BS EN 60695-6-2:2011 | Equivalent |
| EN 50399 : 2011 AMD 1 2016 | COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - HEAT RELEASE AND SMOKE PRODUCTION MEASUREMENT ON CABLES DURING FLAME SPREAD TEST - TEST APPARATUS, PROCEDURES, RESULTS |
| IEC TS 60695-6-31:2013 | Fire hazard testing - Part 6-31: Smoke obscuration - Small-scale static test - Materials |
| NFPA 262 : 2015 | METHOD OF TEST FOR FLAME TRAVEL AND SMOKE OF WIRES AND CABLES FOR USE IN AIR-HANDLING SPACES |
| ISO/TR 5924:1989 | Fire tests — Reaction to fire — Smoke generated by building products (dual-chamber test) |
| EN 50289-4-11:2002 | Communication cables - Specifications for test methods - Part 4-11: Environmental test methods - A horizontal integrated fire test method |
| ISO 5659-2:2017 | Plastics — Smoke generation — Part 2: Determination of optical density by a single-chamber test |
| 89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
| ISO 5660-2:2002 | Reaction-to-fire tests — Heat release, smoke production and mass loss rate — Part 2: Smoke production rate (dynamic measurement) |
| IEC 60695-6-1:2005+AMD1:2010 CSV | Fire hazard testing - Part 6-1: Smoke obscuration - General guidance |
| BS 6401:1983 | Method for measurement, in the laboratory, of the specific optical density of smoke generated by materials |
| ISO 13943:2017 | Fire safety — Vocabulary |
| NFC 20 19902-1 : 1990 | FIRE HAZARD TESTING - TEST METHODS - DETERMINATION OF SMOKE OPACITY WITHOUT AIR-CHANGE - PART 1: METHODOLOGY AND TEST DEVICES |
| EN 61034-2:2005/A1:2013 | MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: TEST PROCEDURE AND REQUIREMENTS (IEC 61034-2:2005/A1:2013) |
| IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
| NFC 20 19902-2-1 : 1990 | FIRE HAZARD TESTING - TEST METHODS - DETERMINATION OF SMOKE OPACITY WITHOUT AIR-CHANGE - PART 2-1: TEST METHODS FOR MATERIALS USED IN ELECTRIC CABLES AND IN OPTICAL FIBER CABLES |
| ASTM E 662 : 2017-02 | TEST METHOD FOR SPECIFIC OPTICAL DENSITY OF SMOKE GENERATED BY SOLID MATERIALS |
| EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
| ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
| EN 61034-1:2005/A1:2014 | MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 1: TEST APPARATUS (IEC 61034-1:2005/A1:2013) |
| EN 60695-6-1:2005/A1:2010 | FIRE HAZARD TESTING - PART 6-1: SMOKE OBSCURATION - GENERAL GUIDANCE |
| ISO 19706:2011 | Guidelines for assessing the fire threat to people |
| IEC 61034-2:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements |
| IEC 60332-3-10:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus |
| IEC 61034-1:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus |
| ASTM E 1354 : 2017 : REDLINE | Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter |