I.S. HD 60269-3:2010
Withdrawn
LOW-VOLTAGE FUSES - PART 3: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO F (IEC 60269-3:2010 (MOD))
Hardcopy , PDF
English
01-01-2010
05-20-2017
FOREWORD
1 General scope
Fuse system A - D type fuse system
Fuse system B - Cylindrical fuses
(NF cylindrical fuse system)
Fuse system C - Cylindrical fuses (BS cylindrical
fuse system)
Fuse system F - Cylindrical fuse-links for use in
plugs (BS plugtop system)
Annex BB (informative) - (for all fuse systems) -
Alternative tests for tests No. 1 and No. 2
of Table 20 of IEC 60269-1
Annex CC (informative) - Recommendations for
future designs of fuses (for all fuse systems)
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Defines fuses for use by unskilled persons according to the following fuse systems comply with all subclauses of IEC 60269-1 and with the requirements laid down in the relevant fuse systems.
| DevelopmentNote |
Supersedes I.S. EN 60269-3. Supersedes I.S. HD 60269-3-1. (06/2007) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
| DocumentType |
Standard
|
| Pages |
345
|
| PublisherName |
National Standards Authority of Ireland
|
| Status |
Withdrawn
|
| Supersedes |
| Standards | Relationship |
| HD 60269-3:2010/A1:2013 | Identical |
| IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
| IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
| IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
| IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
| EN 60898-1:2003/A13:2012 | ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED) |
| IEC 60898-1:2015 | Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation |
| EN 60999-1:2000 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included) |
| ISO 965-1:2013 | ISO general purpose metric screw threads — Tolerances — Part 1: Principles and basic data |
| ISO 228-2:1987 | Pipe threads where pressure-tight joints are not made on the threads — Part 2: Verification by means of limit gauges |
| EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
| ISO 228-1:2000 | Pipe threads where pressure-tight joints are not made on the threads — Part 1: Dimensions, tolerances and designation |
| EN 60898-1:2003/A13:2012 | ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED) |
| EN 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
| EN 60269-1:2007/A2:2014 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014) |