IEC 60034-3:2007
Superseded
View Superseded by
Rotating electrical machines - Part 3: Specific requirements for synchronous generators driven by steam turbines or combustion gas turbines
Hardcopy , PDF
English - French
11-27-2007
12-31-2021
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General
4.1 General rules
4.2 Rated conditions
4.3 Rated voltage
4.4 Power factor
4.5 Rated speed
4.6 Ranges of voltage and frequency
4.7 Direction of rotation
4.8 Stator winding
4.9 Generator rated field current and voltage
4.10 Winding insulation
4.10.1 Thermal class
4.10.2 Withstand voltage tests
4.11 Insulation against shaft current
4.12 Over-speed test
4.13 Critical speeds
4.14 P-Q capability diagram
4.15 Overcurrent requirements
4.16 Sudden short circuit
4.17 Short-circuit ratio
4.18 Direct axis transient and subtransient reactances for
generators
4.19 Tolerances on short-circuit ratio and direct axis
transient and subtransient reactances
4.20 Mechanical conditions for rotors
4.20.1 Number of starts
4.20.2 Turning gear operation
4.21 Coolers
5 Air-cooled generators
5.1 General
5.2 Generator cooling
5.3 Temperature of primary coolant
5.3.1 Temperature detectors
6 Hydrogen-cooled or liquid-cooled generators
6.1 General
6.2 Hydrogen pressure and purity in the casing
6.3 Generator housing and cover plates
6.4 Stator winding terminals
6.5 Temperature of primary coolants, temperatures and
temperature rises of the generator
6.6 Temperature detectors
6.7 Auxiliary system
7 Generators for combustion gas turbines or combined
cycle applications
7.1 General
7.2 Service conditions
7.2.1 General
7.2.2 Primary coolant temperature
7.2.3 Number of starts
7.2.4 Application of load
7.3 Rated output
7.4 Capabilities
7.4.1 General
7.4.2 Base capability
7.4.3 Temperature rise and temperature at base
capability
7.4.4 Peak capability
7.5 Rating plate
7.6 Temperature tests
Annex A (normative) Precautions to be taken when using
hydrogen cooled turbine-driven synchronous
generators
Bibliography
Applies to three-phase synchronous generators, having rated outputs of 10 MVA and above driven by steam turbines or combustion gas turbines. Provides common requirements as well as specific requirements for air, hydrogen or liquid cooled synchronous generators and supplements the basic requirements given in IEC 60034-1. Gives also the precautions to be taken when using hydrogen cooled generators. The scope of this new edition has been limited with respect to the previous edition.
| Committee |
TC 2
|
| DevelopmentNote |
Supersedes IEC 60842. (04/2006) Stability date: 2017. (09/2017)
|
| DocumentType |
Standard
|
| Pages |
54
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| GOST IEC 60034-3 : 2015 | Identical |
| NEN EN IEC 60034-3 : 2008 | Identical |
| VDE 0530-3 : 2009 | Identical |
| BIS IS 15999-3 : 2016 | Identical |
| NF EN 60034-3 : 2008 | Identical |
| BS 5000-2(1992) : 1992 AMD 9035 | Similar to |
| PN EN 60034-3 : 2008 | Identical |
| UNE 20113-3:1994 | Identical |
| I.S. EN 60034-3:2008 | Identical |
| CEI EN 60034-3 : 2011 | Identical |
| NEN 10034-3 : 1996 | Similar to |
| EN 60034-3:2008 | Identical |
| UNE-EN 60034-3:2008 | Identical |
| BS EN 60034-3:2008 | Identical |
| HD 53-3 : 200S1 | Similar to |
| DIN EN 60034-3 : 2009 | Identical |
| BS EN 60297-3-102:2004 | Identical |
A newer version of this standard is available.
View Current Edition