IEC 60044-2:1997+AMD1:2000+AMD2:2002 CSV
Superseded
View Superseded by
Instrument transformers - Part 2 : Inductive voltage transformers
Hardcopy , PDF
English - French, English, French
02-13-2003
07-13-2011
FOREWORD
1 General
1.1 Scope
1.2 Normative references
2 Definitions
2.1 General definitions
2.2 Additional definitions for single-phase
inductive protective voltage transformers
3 General requirements
4 Normal and special service conditions
4.1 Normal service conditions
4.2 Special service conditions
4.3 System earthing
5 Ratings
5.1 Standard values of rated voltages
5.2 Standard values of rated output
5.3 Standard values of rated voltage factor
5.4 Limits of temperature rise
6 Design requirements
6.1 Insulation requirements
6.2 Short-circuit withstand capability
6.3 Mechanical requirements
7 Classification of tests
7.1 Type tests
7.2 Routine tests
7.3 Special tests
8 Type tests
8.1 Temperature-rise test
8.2 Short-circuit withstand capability test
8.3 Impulse test on primary winding
8.4 Wet test for outdoor type transformers
8.5 Radio interference voltage measurement
9 Routine tests
9.1 Verification of terminal markings
9.2 Power-frequency withstand tests on primary
windings and partial discharge measurement
9.3 Power-frequency withstand tests between
sections and on secondary windings
10 Special tests
10.1 Chopped impulse test on primary winding
10.2 Measurement of capacitance and dielectric
dissipation factor
10.3 Mechanical tests
10.4 Transmitted overvoltage measurement
11 Markings
11.1 Rating plate markings
11.2 Terminal markings
12 Accuracy requirements for single-phase inductive
measuring voltage transformers
12.1 Accuracy class designation for measuring
voltage transformers
12.2 Limits of voltage error and phase displacement
for measuring voltage transformers
12.3 Type tests for accuracy of measuring voltage
transformers
12.4 Routine tests for accuracy of measuring voltage
transformers
12.5 Marking of the rating plate of a measuring voltage
transformer
13 Additional requirements for single-phase inductive
protective voltage transformers
13.1 Accuracy class designation for protective voltage
transformers
13.2 Limits of voltage error and phase displacement
for protective voltage transformers
13.3 Rated voltages for secondary windings intended to
produce a residual voltage
13.4 Output for secondary windings intended to produce
a residual voltage
13.5 Accuracy class for secondary windings intended to
produce a residual voltage
13.6 Type tests for protective voltage transformers
13.7 Routine tests for protective voltage transformers
13.8 Marking of the rating plate of a protective
voltage transformer
Figures
Tables
Applies to new inductive voltage transformers for use withelectrical measuring instruments and electrical protective devicesat frequencies from 15 to 100 Hz. This standard relates basically to transformers with separate windings, but also to autotransformers.It replaces IEC 60186 (1987) plus Amendments 1 and 2only for inductive voltage transformers. IEC 60186 remains in forcefor capacitive voltage transformers.This consolidated version consists of the first edition (1997),its amendment 1 (2000) and its amendment 2 (2002). Therefore, no need to order amendments in addition to this publication.
| Committee |
TC 38
|
| DevelopmentNote |
Also numbered as BS EN 60044-2 (08/2001) Supersedes IEC 60186. (06/2004)
|
| DocumentType |
Standard
|
| Pages |
97
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| NF EN 60044-2 : 2000 AMD 2 2003 | Identical |
| NEN EN IEC 60044-2 : 2000 AMD 2 2003 | Identical |
| I.S. EN 60044-2:1999 | Identical |
| VDE 0414-44-2 : 2003 COR 1 2003 | Identical |
| VDE 0414-2 : 99 AMD 1 2001 | Identical |
| UNE-EN 60044-2:1999 | Identical |
A newer version of this standard is available.
View Current Edition