IEC 60127-6:2014
Superseded
View Superseded by
Miniature fuses - Part 6: Fuse-holders for miniature fuse-links
Hardcopy , PDF
English - French
09-03-2014
10-26-2023
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Preferred standard ratings and classifications
for fuse-holders
6 Marking
7 Clause deleted
8 General notes on tests
9 Protection against electric shock
10 Clearances and creepage distances
11 Electrical requirements
12 Mechanical requirements
13 Thermal requirements
14 Endurance
15 Additional requirements
Annex A (normative) - Test PC board for fuse-holders
of rated currents up to 10 A
Annex B (normative) - Type tests, test sequences and
number of samples
Annex C (informative) - Insulation coordination
Annex D (informative) - Additional tests and
requirements
Annex E (informative) - Information for the correct
application of the fuse-holder
Bibliography
IEC 60127-6:2014 is applicable to fuse-holders for miniature cartridge fuse-links according to IEC 60127-2 and sub-miniature fuse-links according to IEC 60127-3 for the protection of electric appliances, electronic equipment and component parts thereof, normally intended for use indoors. Examples of fuse-holder types with different features are given. This part of IEC 60127 applies to fuse-holders with:
- a maximum rated current of 16 A; and
- a maximum rated voltage of 1 500 V d.c. or 1 000 V a.c.; and
- for use up to 2 000 m above sea-level, unless otherwise specified. The object of this standard is to establish uniform requirements for safety and the assessment of electrical, mechanical, thermal and climatic properties of fuse-holders and the compatibility between fuse-holders and fuse-links. This second edition cancels and replaces the first edition published in 1994, its Amendment 1 (1996) and Amendment 2 (2002). This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- modify the arrangement of the fuse-holder samples in the planes in 13.1.1;
- add a new test 13.2.2: Glow-wire ignition test;
- change maximum gauge size for standard sheets 3 and 4 from 0,70 to 0,63 in table 5;
- change minimum gauge size for standard sheets 3 and 4 from 0,55 to 0,56 in table 5. Keywords: fuse-holders for miniature cartridge fuse-links, sub-miniature fuse-links, protection of electric appliances, electronic equipment and component parts.
| Committee |
TC 32/SC 32C
|
| DevelopmentNote |
Supersedes IEC 60257 (03/2001) Stability date: 2019. (09/2017)
|
| DocumentType |
Standard
|
| Pages |
110
|
| PublisherName |
International Electrotechnical Committee
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| GOST IEC 60127-6 : 2013 | Identical |
| NBN EN 60127-6 : 2014 | Identical |
| NEN EN IEC 60127-6 : 2014 | Identical |
| PN EN 60127-6 : 2015 | Identical |
| BS EN 60127-6:2014 | Identical |
| EN 60127-6:2014 | Identical |
| NF EN 60127-6 : 2014 | Identical |
| I.S. EN 60127-6:2014 | Equivalent |
| CEI EN 60127-6 : 2015 | Identical |
| DS EN 60127-6 : 2014 | Identical |
| UNE-EN 60127-6:1997 | Identical |
| GOST R IEC 127-6 : 1999 | Identical |
| UNE-EN 60127-6:2014 | Identical |
| NEN 10127-6 : 1994 AMD 1 1996 | Identical |
| BIS IS/IEC 127-6 : 1994(R2007) | Identical |
| DIN EN 60127-6 : 2015 | Identical |
| VDE 0820-6 : 2015 | Identical |
| CEI EN 60127-6 : 2016 | Identical |
A newer version of this standard is available.
View Current Edition View Current Edition View Current Edition