Summarise this standard

FOREWORD
INTRODUCTION
SECTION 1: GENERAL
Clause
1.1 Scope and object
1.2 Normative references
1.3 Definitions
SECTION 2: INSULATORS
2.1 Insulator designs and insulating materials
2.2 Values which characterize a post insulator
2.3 Identification of insulators
SECTION 3: CLASSIFICATION OF THE TESTS,
SAMPLING RULES AND PROCEDURES
3.1 Classification of the tests
3.2 Quality assurance
3.3 General requirements for type tests
3.4 General requirements for sample tests
SECTION 4: TEST PROCEDURES FOR ELECTRICAL TESTS
4.1 General requirements for high-voltage tests
4.2 Standard atmospheric conditions and correction
     factors for electrical tests
4.3 Artificial rain parameters for wet tests
4.4 Mounting arrangements for electrical tests
4.5 Dry lightning-impulse withstand voltage test -
     Type test
4.6 Dry or wet switching-impulse withstand voltage
     tests - Type test
4.7 Dry power-frequency withstand voltage test - Type
     test (applicable only to post insulators for
     indoor use)
4.8 Wet power-frequency withstand voltage test - Type
     test (applicable only to post insulators for
     outdoor use)
4.9 Puncture test - Sample test
4.10 Routine electrical test
SECTION 5: TEST PROCEDURES FOR MECHANICAL AND OTHER TESTS
5.1 Verification of the dimensions - Type and sample test
5.2 Mechanical failing load test - Type and sample test
5.3 Test for deflection under load - Special type test
5.4 Temperature cycle test - Sample test
5.5 Routine thermal shock test (applicable only to
     toughened glass insulating parts)
5.6 Porosity test - Sample test (applicable only to
     ceramic post insulators)
5.7 Galvanizing test - Sample test
5.8 Routine visual inspection
5.9 Routine mechanical test
SECTION 6: TESTS APPLICABLE TO POST INSULATORS
6.1 Type tests
6.2 Sample tests
6.3 Routine tests
6.4 Summary of tests on post insulators
Annex A (informative) Methods of testing for tolerances
        of parallelism, eccentricity, angular deviation,
        camber, and shed angle of post insulators
Annex B (informative) Methods of routine testing of
        unassembled insulator units
Annex C (informative) Bibliography

Applies to post insulators and post insulator units of ceramic material or glass for indoor and outdoor service in electrical installations or equipment operating on alternating current with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. Notes: -May also be regarded as a provisional standard for insulators for use on d.c. systems, see IEC 60438. -When considering hollow insulators, see IEC 60233. -Tests on indoor post insulators of organic material will be covered by a future publication: Tests on indoor post insulators of organic material for systems with nominal voltages greater than 1 000 V up to but not including 300 kV. -For artificial pollution and radio-interference tests, see IEC 60437 and 60507. -For numerical values for insulator characteristics and for selection of insulators for specific operating conditions, see IEC 60273. This consolidated version consists of the fourth edition (1994), its amendment 1 (1997) and its amendment 2 (2000). Therefore, no need to order amendments in addition to this publication.